Page 61
CHAPTER 3 SYSTEM DATA PROGRAMMING Digital Trunk Interface Assignment NEAX2000 IVS2 Data Interface System Manual ND-70924 (E), Issue 1.0 Page 53 DESCRIPTION DATA Specify the kind of digital data transmission. (1) (2)YY=92 00-63: Trunk Route No. 0 : Digital Data Transmission (48 kbps) 1 : Digital Data Transmission (56 kbps) 2 : Digital Data Transmission (Transparent) 3 : Reversal of F&S Bits 7 : Data Transmission via ModemCM35 C END
Page 62
NEAX2000 IVS2 Data Interface System Manual ND-70924 (E), Issue 1.0 Page 55 CHAPTER 4 OPERATION TEST This chapter explains the operation tests to be performed after you have completed the installation of the Data Interface to the PBX.
Page 63
NEAX2000 IVS2 Data Interface System ManualPage 56 ND-70924 (E), Issue 1.0 CHAPTER 4 OPERATION TEST DPC Loopback Test DPC LOOPBACK TEST This test is the intra-office loopback test on the DPC card using a modem tester. There are two kinds of loopback (Loopback 1, Loopback 2) as shown in Figure 4-1. Either the Loopback 1 or the Loopback 2 can be selected by switch settings on the DPC card. Figure 4-1 DPC Loopback Tests V.110DPC V.110DPC Loopback 1 PBX MODEM TESTER DTI Loopback 2 MODEM TESTER DTI NOTE:The...
Page 64
CHAPTER 4 OPERATION TEST DPC Loopback Test NEAX2000 IVS2 Data Interface System Manual ND-70924 (E), Issue 1.0 Page 57 DPC Loopback 1 Test (1) Set the SW1 on the DPC card as shown below. (2) Confirm whether the LB01 lamp (for No. 0 circuit) or the LB11 lamp (for No. 1 circuit) on the DPC card lights. If the LB01 lamp or the LB11 lamp does not light, check the switch settings on the DPC card and the system data assignment. (3) Connect a modem tester to the DPC card as shown in Figure 4-2. Figure...
Page 65
NEAX2000 IVS2 Data Interface System ManualPage 58 ND-70924 (E), Issue 1.0 CHAPTER 4 OPERATION TEST DPC Loopback Test (4) Set the attributes of modem tester (transmission rate, etc.). (5) To confirm whether the data is transmitted correctly, send the PN Pattern 9 (511 Pattern) from the modem tester. (6) Count bit errors on the modem tester for 1 minute. If bit errors do not occur, the cable connection between DPC card and modem tester is normal. (7) If bit errors occur, check the cable connection,...
Page 66
CHAPTER 4 OPERATION TEST DPC Loopback Test NEAX2000 IVS2 Data Interface System Manual ND-70924 (E), Issue 1.0 Page 59 DPC Loopback 2 Test After you complete the DPC Loopback 1 Test, do the following steps. (1) Set the SW1 on the DPC card as shown below. (2) Confirm whether the LB02 lamp (for No. 0 circuit) or the LB12 lamp (for No. 1 circuit) on the DPC card lights. If the LB02 lamp or the LB12 lamp does not light, check the switch settings on the DPC card and the system data assignment. (3)...
Page 67
NEAX2000 IVS2 Data Interface System ManualPage 60 ND-70924 (E), Issue 1.0 CHAPTER 4 OPERATION TEST Other Loopback Tests OTHER LOOPBACK TESTS Two additional forms of loopback test are shown in Figure 4-3. Figure 4-3 Other Loopback Tests V.110DPC DTI local loopback PBX DTI DTI hard-wired loopback Set DTI in local loopback. DTI TA TB RA RB On the MDF, connect transmit leads to the Receive leads to test all portions of the DTI. V.110DPC MODEM TESTER MODEM TESTER
Page 68
CHAPTER 4 OPERATION TEST Inter-Office Digital Data Transmission Test NEAX2000 IVS2 Data Interface System Manual ND-70924 (E), Issue 1.0 Page 61 INTER-OFFICE DIGITAL DATA TRANSMISSION TEST This test is the inter-office digital data transmission test using modem testers. After you complete the loopback tests, do the following steps. (1) Connect modem testers to the both PBXs as shown in Figure 4-4. Figure 4-4 Inter-Office Digital Data Transmission Test (2) Set the attributes of both modem testers...
Page 69
NEAX2000 IVS2 Data Interface System Manual ND-70924 (E), Issue 1.0 Page 63 CHAPTER 5 CIRCUIT CARD INFORMATION This chapter explains the mounting location, the meaning of lamp indications, and the method of switch settings of each circuit card for the Data Interface system.
Page 70
NEAX2000 IVS2 Data Interface System ManualPage 64 ND-70924 (E), Issue 1.0 CHAPTER 5 CIRCUIT CARD INFORMATION How to Read This Chapter HOW TO READ THIS CHAPTER This chapter explains each circuit card used in this system for the following items. Explanations are given in the alphabetical order of the circuit card names within each circuit card category (Control, Application Processor, and Line/Trunk). (1) Locations of Lamps, Switches, and Connectors The locations of lamps, switches, and connectors of...