CHAPTER 2 INSTALLATION Installation Procedure for Data Interface NEAX2000 IVS2 Data Interface System Manual ND-70924 (E), Issue 1.0 Page 33 Connecting V.35 DTE (1) Connect the M03 card and the DPC card as shown in Figure 2-13. (2) Connect the V.35 DTE/modem to the M03 card in the following pages. Figure 2-13 Outline of V.35 Cable Connection DPC V. 3 5 DTE/ 17-TW-0.3 CONN CABLE DPC V35 CABLE M03 PBX V.35 INTERFACE CABLE MODEM XCN0/XCN1 CONNECTOR X21 CONNECTOR V35 CONNECTOR (LOCALLY PROVICED)
Page 42
NEAX2000 IVS2 Data Interface System ManualPage 34 ND-70924 (E), Issue 1.0 CHAPTER 2 INSTALLATION Installation Procedure for Data Interface Figure 2-14 Cable Connection between M03 Card and V.35 DTE/Modem NOTE:When you provide V.35 DTE using TXC(1) signal, this connection is required. (Continued) V35 CONNECTOR STRAIGHT CABLE (LOCALLY PROVIDED) M03 V. 3 5 DTE (J) (J) (P) (P) 4 m (13.1 ft.) MAX 15 m (49.2 ft.) TXD 4A 4B RXD 2A 2B RTS 6A CTS 6B DSR 5A GND 6D DCD 5B TXC(2) 3A 3B RXC 1C 2D DTR 5C TXC(1) 3C...
Page 43
CHAPTER 2 INSTALLATION Installation Procedure for Data Interface NEAX2000 IVS2 Data Interface System Manual ND-70924 (E), Issue 1.0 Page 35 Figure 2-15 Cable Connection between M03 Card and V.35 DTE/Modem V35 CONNECTOR REVERSE CABLE (LOCALLY PROVIDED) M03 V.35 MODEM (J) (J) (P) (P) 4 m (13.1 ft.) MAX 15 m (49.2 ft.) TXD 4A 4B RXD 2A 2B RTS 6A CTS 6B DSR 5A GND 6D DCD 5B TXC(2) 3A 3B RXC 1C 2D DTR 5C TXC(1) 3C 4D TXD P S RXD R T RT S C CTS D DSR E GND B GND A DCD F TXC(2) Y AA RXC V X DTR H TXC(1)...
Page 44
NEAX2000 IVS2 Data Interface System ManualPage 36 ND-70924 (E), Issue 1.0 CHAPTER 2 INSTALLATION Installation Procedure for Data Interface Figure 2-16 DPC V35 Cable DA (J)(J) 1 6B NN 6D-GND 2A-RXDA 2B-RXDB 4A-TXDA 4B-TXDB 6A-RTS 6B-CTS 3C-TXC(1)A 4D-TXC(1)B 3A-TXC(2)A 3B-TXC(2)B 5A-DSR 5B-DCD 1C-RXCA 6 5 4 3 2 1RTS DSR TXDA TXC(2)A RXDA GA CTS DCD TXDB TXC(2)B RXDBB DTR TXC(1)A RXCAC GND TXC(1)B RXCBD X: NOT CONNECTED G: GROUND 2D-RXCB 5C-DTR 1A-GNDB-GND R-RXDA T-RXDB P-TXDA S-TXDB C-RTS D-CTS...
Page 45
CHAPTER 2 INSTALLATION Installation Procedure for Data Interface NEAX2000 IVS2 Data Interface System Manual ND-70924 (E), Issue 1.0 Page 37 Figure 2-17 V.35 Connector Pin Assignment Table 2-3 V.35 Interface Cable Connector Pin Assignments Pin Name Function Specification Source A B C D E F HGND GND RTS CTS DSR RLSD DTRFrame Ground Signal Ground Request To Send Clear To Send Data Set Ready Received Line Signal Detector Data Terminal Ready— — RS-232 RS-232 RS-232 RS-232 RS-232— — DTE DCE DCE DCE...
Page 46
NEAX2000 IVS2 Data Interface System ManualPage 38 ND-70924 (E), Issue 1.0 CHAPTER 2 INSTALLATION Installation Procedure for Data Interface INSTALLATION PROCEDURE FOR DIGITAL TRUNK INTERFACE Installation Summary for Digital Trunk Interface Install the equipment according to the procedure shown in Figure 2-18. Figure 2-18 Installation Procedure for DTI NOTE:This procedure is required when you provide CONN card to connect a coaxial cable for 30DTI. START Selection of PLO in MP Card Mounting DTI Card DTI...
Page 47
CHAPTER 2 INSTALLATION Installation Procedure for Data Interface NEAX2000 IVS2 Data Interface System Manual ND-70924 (E), Issue 1.0 Page 39 Mounting DTI Card (1) Before mounting the DTI (PN-24DTA-C/PN-30DTC-A) card, set the MB switch to UP position, and set the other switches to appropriate position. See CHAPTER 5.Page 63 (2) Mount the DTI card in the following AP slots on PIM0-PIM7. PIM0: AP00-AP10 slots PIM1-7: AP00-AP11 slots After mounting the card, set the MB to DOWN position to put the card...
Page 48
NEAX2000 IVS2 Data Interface System ManualPage 40 ND-70924 (E), Issue 1.0 CHAPTER 2 INSTALLATION Installation Procedure for Data Interface DTI Cable Connection via MDF When you use a twisted-pair cable, connect the cable to a CSU via the MDF as shown below. Location of AP Slots and LTC Connectors for DTI - Page 41 Example of MDF Cross Connection for DTI - Page 42 Figure 2-19 DTI Cable Connection via MDF CSU MDF LTC0/LTC1/LTC2/LTC3 CONNECTORTWISTED-PAIR CABLE BWBPBX (PIM0-PIM7) MAX. 200 m (655...
Page 49
CHAPTER 2 INSTALLATION Installation Procedure for Data Interface NEAX2000 IVS2 Data Interface System Manual ND-70924 (E), Issue 1.0 Page 41 Figure 2-20 Location of the AP Slots and the LTC Connectors for DTI LTC0 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25RA TA RA TA RA TA MJ RB TB RB TB RB TB MNRA TA RA TA RA TA RB TB RB TB...
Page 50
NEAX2000 IVS2 Data Interface System ManualPage 42 ND-70924 (E), Issue 1.0 CHAPTER 2 INSTALLATION Installation Procedure for Data Interface Figure 2-21 Example of MDF Cross Connection for DTI 17 18 19 20RA TA42 43 44 45RB TB LTC1 (J)42 43 44 45RB TB17 18 19 20RA TA LTC1 (P) PIM 0 JP MDF DTI AP05 RA RB TA TB17 42 18 4317 42 18 43RA RB TA TBTO CSU LTC1 RECEIVE TRANSMIT