CHAPTER 1 GENERAL INFORMATION
System Conditions
NEAX2000 IVS2 Data Interface System Manual    
ND-70924 (E), Issue 1.0   Page 13
SYSTEM CONDITIONS
Time Slot Assignment Condition
As shown in Figure 1-4, the 30DTI card uses the time slot on the basic Highway 4.
Therefore, the total number of time slots for all 30DTI card must be 128 time slots or less
including all other application processor cards which use the Highway 4.
The 24DTI card can use the time slot on both the basic and expanded Highway 4 and...

Page 22

 NEAX2000 IVS2 Data Interface System ManualPage 14  ND-70924 (E), Issue 1.0
CHAPTER 1 GENERAL INFORMATION
System Conditions
Time Slot Allocation for DTI Card
On each DTI card, the system recognizes the lowest and highest channel numbers to which trunk
numbers have been assigned, and allocates time slots to all the channels within them. If trunk
numbers are assigned to discontinuous channels in this case, the system also allocates time
slots to channels not assigned.
For example, as shown in Figure 1-5,...

Page 23

NEAX2000 IVS2 Data Interface System Manual    
ND-70924 (E), Issue 1.0   Page 15
CHAPTER 2
INSTALLATION
This chapter explains the hardware installation procedure to provide
Data Interface to the PBX. 

Page 24

 NEAX2000 IVS2 Data Interface System ManualPage 16  ND-70924 (E), Issue 1.0
CHAPTER 2 INSTALLATION
Precautions
PRECAUTIONS
Static Electricity Guard
You must wear a grounded wrist strap to protect circuit cards from static electricity.
Figure 2-1  Static Electricity Guard (1 of 2)
 WHEN PLUGGING/UNPLUGGING A CIRCUIT CARD
 WHEN HOLDING A CIRCUIT CARD
PBX
WRIST STRAP
FRAME GROUND SCREW
CARD FRONT
NEVER TOUCH THE COMPONENTS OR 
SOLDERED SURFACE WITH BARE HANDS. 

Page 25

CHAPTER 2 INSTALLATION
Precautions
NEAX2000 IVS2 Data Interface System Manual    
ND-70924 (E), Issue 1.0   Page 17
Figure 2-1  Static Electricity Guard (2 of 2)
 WHEN MAKING A SWITCH SETTING ON A CIRCUIT CARD
 WHEN CARRYING A CIRCUIT CARD
The mark shown below is attached to the sheet for the work in which circuit cards are handled.
When engaging in such work, the installer must be careful not to cause damage by static
electricity.
WEAR A WRIST STRAP AND PERFORM
THE WORK ON A GROUNDED
CONDUCTIVE WORK...

Page 26

 NEAX2000 IVS2 Data Interface System ManualPage 18  ND-70924 (E), Issue 1.0
CHAPTER 2 INSTALLATION
Precautions
Caution
You must hold the edge of a circuit card when plugging or unplugging the circuit card. If you 
touch another area, you may be exposed to hazardous voltages.
CARD FRONT
NEVER TOUCH THE COMPONENTS OR
SOLDERED SURFACE WITH BARE
HANDS.
PBX 

Page 27

CHAPTER 2 INSTALLATION
Required Equipment
NEAX2000 IVS2 Data Interface System Manual    
ND-70924 (E), Issue 1.0   Page 19
REQUIRED EQUIPMENT
Table 2-1 shows the equipment required to provide the Data Interface on the system.
Table 2-1  Required Equipment
EQUIPMENT/CABLE DESCRIPTION QTY REMARKS
 PN-2DPCB Data Port Controller Card 1-50
 PN-24DTA-C 24 channel DTI Card 1-8 For Inter-office
 PN-30DTC-A 30 channel DTI Card 1-4 For Inter-office
 PN-M03 V.35 DTE Interface Card 1-50
 PZ-M542/M557 Coaxial...

Page 28

 NEAX2000 IVS2 Data Interface System ManualPage 20  ND-70924 (E), Issue 1.0
CHAPTER 2 INSTALLATION
Installation Procedure for Data Interface
INSTALLATION PROCEDURE FOR DATA INTERFACE
Installation Summary for Data Interface
Install the equipment according to the procedure shown in Figure 2-2.
Figure 2-2  Installation Procedure for Data Interface
START
Mounting DPC Card
END
Page 21
Mounting M03 CardConnecting X.21 DTEConnecting RS-449 
Which
type of DTE?
DTE Connecting V.24/V.28
DTE
Connecting V.35 DTE...

Page 29

CHAPTER 2 INSTALLATION
Installation Procedure for Data Interface
NEAX2000 IVS2 Data Interface System Manual    
ND-70924 (E), Issue 1.0   Page 21
Mounting DPC Card
(1) Confirm the correct switch settings of the DPC card. 
See CHAPTER 5. Page 63.
(2) Mount the DPC cards in LT00 through LT11 slots of PIM0 through PIM7.
Mounting M03 Card
(1) Confirm the correct switch settings of the M03 card. 
See CHAPTER 5. Page 63.
(2) Mount the M03 cards in LT00 through LT11 slots of PIM0 through PIM7....

Page 30

 NEAX2000 IVS2 Data Interface System ManualPage 22  ND-70924 (E), Issue 1.0
CHAPTER 2 INSTALLATION
Installation Procedure for Data Interface
Conditions on Connecting DTE
Forcible ON control of DTR, RTS/C signal:
When connecting the DTE which does not support the DTR signal and RTS/C signal, these
signals can be turned to ON forcibly by switch setting on the DPC card.
Condition of CTS signal ON control:
The CTS signal is turned to ON after 60 ms from the time when receiving the RTS/C signal. And
the CTS...