NEC Neax 2000 Ivs2 Data Interface System Manual
Here you can view all the pages of manual NEC Neax 2000 Ivs2 Data Interface System Manual. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 11
NEAX2000 IVS2 Data Interface System Manual ND-70924 (E), Issue 1.0 Page 3 CHAPTER 1 GENERAL INFORMATION This chapter explains the Data Interface system outline, the name and functions of circuit cards required, system capacity, specifications, and conditions.
Page 12
NEAX2000 IVS2 Data Interface System ManualPage 4 ND-70924 (E), Issue 1.0 CHAPTER 1 GENERAL INFORMATION System Outline SYSTEM OUTLINE The Data Interface can provide the intra- or inter-office digital data transmission on fixed path (Nailed-Down) connection. The Data Interface equips the V.11 (X.21) and the V.24/V.28 (RS-232C) interface. When you use the V.11 (X.21) interface, a maximum of 64 kbps digital data transmission is available. When you use the V.24/V.28 (RS-232C) interface, a maximum of 19.2...
Page 13
CHAPTER 1 GENERAL INFORMATION System Outline NEAX2000 IVS2 Data Interface System Manual ND-70924 (E), Issue 1.0 Page 5 When the PBX is an end office in the Inter-Office Digital Data Transmission through Nailed-Down Connection, the digital signal is transmitted directly. A maximum of 64 kbps digital data transmission is available for the direct digital transmission. When the PBX is a tandem office in the Inter-Office Digital Data Transmission through Nailed- Down Connection, data transparency is...
Page 14
NEAX2000 IVS2 Data Interface System ManualPage 6 ND-70924 (E), Issue 1.0 CHAPTER 1 GENERAL INFORMATION System Outline Figure 1-2 System Outline of Inter-Office Data Connection DTI PBX (2) PBX IS A NTANDEM OFFICE: DTI PBX DTE DPC DPC DPC : DATA PORT CONTROLLER DTE : DATA TERMINAL EQUIPMENT DTI : 24/30 CHANNEL DIGITAL TRUNK INTERFACE M: MODEM PLO : PHASE LOCKED OSCILLATOR DTE DPC MM TO DTE DTI MPPLO NAILED-DOWN CONNECTION 24/30 CHANNEL PCM DIGITAL LINE DIGITAL PBX CLOCK SIGNAL TDSW (1) PBX IS AN END...
Page 15
CHAPTER 1 GENERAL INFORMATION System Outline NEAX2000 IVS2 Data Interface System Manual ND-70924 (E), Issue 1.0 Page 7 DPC The Data Port Controller (DPC) can accommodate a maximum of two DTE per cards with V.11 (X.21) or V.24/V.28 (RS-232C) interface, and can provide the intra-office or inter-office digital data transmission on Nailed-Down connection. DTI The Digital Trunk Interface (DTI) interfaces the PBX directly to a 24/30-channel PCM transmission line. The DTI has the following functions. For...
Page 16
NEAX2000 IVS2 Data Interface System ManualPage 8 ND-70924 (E), Issue 1.0 CHAPTER 1 GENERAL INFORMATION System Outline PLO The Phase Locked Oscillator (PLO) equipped on the MP card synchronizes the system to the digital network clock. When the PBX is a clock receiver office, the PLO generates the clock signals according to the source clocks received from the source office within the network. The source clock signals are extracted at DTI cards and supplied to the PLO. Two clock routes are available; one...
Page 17
CHAPTER 1 GENERAL INFORMATION Card Name and Function NEAX2000 IVS2 Data Interface System Manual ND-70924 (E), Issue 1.0 Page 9 CARD NAME AND FUNCTION Table 1-2 shows the circuit card name and function for Data Interface. Table 1-2 Card Name and Function EQUIPMENT NAMEFUNCTIONAL NAMEFUNCTION PN-CP14 MP Main Processor Card Provides Memory, TDSW (1024CH × 1024CH), 16-line CFT, PB sender, Clock, PLO 2 ports (receiver mode/ source mode), two RS-232C ports, 2-line DAT (Recording duration: Max. 128...
Page 18
NEAX2000 IVS2 Data Interface System ManualPage 10 ND-70924 (E), Issue 1.0 CHAPTER 1 GENERAL INFORMATION Card Name and Function PN-2DPCB DPC 2-line Data Port Controller Card Used for the intra-office or inter-office digital data transmission on nailed down connection. Accommodates max. two DTEs with V.11 (X.21) interface or V.24/V.28 (RS-232C) interface. PN-M03 M03 V.35 Data Terminal Equipment Interface Card Used together with the PN-2DPCB card to provide the V.35 interface. Table 1-2 Card Name and...
Page 19
CHAPTER 1 GENERAL INFORMATION System Capacity NEAX2000 IVS2 Data Interface System Manual ND-70924 (E), Issue 1.0 Page 11 SYSTEM CAPACITY System Capacity for Data Interface System Capacity for Digital Trunk Interface Table 1-3 System Capacity for Data Interface DESCRIPTION CAPACITY REMARKS DPC Card 50 Circuits per DPC Card 2 Fixed Path Connection 100 Table 1-4 System Capacity for Digital Trunk Interface DESCRIPTIONCAPACITY REMARKS 24DTI 30DTI DTI Card 8 4 DTI Trunk 192 124 DTI Trunk Route 64 64 1...
Page 20
NEAX2000 IVS2 Data Interface System ManualPage 12 ND-70924 (E), Issue 1.0 CHAPTER 1 GENERAL INFORMATION System Specifications SYSTEM SPECIFICATIONS DPC Specifications NOTE 1:When the transmission rate is 56 or 64 kbps, only full duplex is available. NOTE 2:For the transmission rate after Rate Adaptation, see Table 1-6. Modem Specifications NOTE:When the transmission rate is 56 or 64 kbps, only full duplex is available. Table 1-5 DPC Specifications DESCRIPTION SPECIFICATION Synchronization Synchronous...