Page 91
CHAPTER 5 CIRCUIT CARD INFORMATION List of Required Circuit Cards NEAX2000 IVS2 Data Interface System Manual ND-70924 (E), Issue 1.0 Page 85 Switch Settings The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK JP0 For coaxial connectors (No.0...
Page 92
NEAX2000 IVS2 Data Interface System ManualPage 86 ND-70924 (E), Issue 1.0 CHAPTER 5 CIRCUIT CARD INFORMATION List of Required Circuit Cards PZ-M557 (CONN) Locations of Lamps, Switches and Connectors Lamp Indications This card has no lamps. JP2 RCV20 FOR No.2 CIRCUIT LT CJP1LTTO LTC CONNECTOR ON BWB IN PIM TO CHAMP CONNECTOR (MDF) JP0 TRS20 TRS00 FOR No.0 CIRCUIT COAXIAL CONNECTORRCV00RCV10 FOR No.1 CIRCUIT TRS10
Page 93
CHAPTER 5 CIRCUIT CARD INFORMATION List of Required Circuit Cards NEAX2000 IVS2 Data Interface System Manual ND-70924 (E), Issue 1.0 Page 87 Switch Settings The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK JP0 For coaxial connectors (No. 0...
Page 94
NEAX2000 IVS2 Data Interface System ManualPage 88 ND-70924 (E), Issue 1.0 CHAPTER 5 CIRCUIT CARD INFORMATION List of Required Circuit Cards PN-2DPCB (DPC) Location of Lamps, Switches and Connectors SW0 XCN1 XCN0 RS1 RS0BL1 LB11 LB12 RSC1 SDT1 RDR1 CDI1 RSC0 SDT0 RDR0 CDI0BL0 LB01 LB02 SW1 To X.21 DTE/DCE or PN-M03 To V.24/V.28 DTE/DCE
Page 95
CHAPTER 5 CIRCUIT CARD INFORMATION List of Required Circuit Cards NEAX2000 IVS2 Data Interface System Manual ND-70924 (E), Issue 1.0 Page 89 Lamp Indications LAMP NAMECOLOR FUNCTION BL0 Red No. 0 CircuitON: Ready for digital data transmission or the circuit is busy. OFF: Fixed path is not connected. Flash (60IPM): Make-busy state or the system data for this card is not assigned. Flash (120IPM): Fixed path is connected. LB01 Red ON: Loop Back 1 is set. OFF: Normally operating. LB02 Red ON:...
Page 96
NEAX2000 IVS2 Data Interface System ManualPage 90 ND-70924 (E), Issue 1.0 CHAPTER 5 CIRCUIT CARD INFORMATION List of Required Circuit Cards Switch SettingsBL1 Red No. 1 CircuitON: Ready for digital data transmission or the circuit is busy. OFF: Fixed path is not connected. Flash (60IPM): Make-busy state or the system data for this card is not assigned. Flash (120IPM): Fixed path is connected. LB11 Red ON: Loop Back 1 is set. OFF: Normally operating. LB12 Red ON: Loop Back 2 is set. OFF: Normally...
Page 97
CHAPTER 5 CIRCUIT CARD INFORMATION List of Required Circuit Cards NEAX2000 IVS2 Data Interface System Manual ND-70924 (E), Issue 1.0 Page 91 The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. NOTE:When the power is on, disconnect the cables before unplugging the circuit card, and connect the cables after...
Page 98
NEAX2000 IVS2 Data Interface System ManualPage 92 ND-70924 (E), Issue 1.0 CHAPTER 5 CIRCUIT CARD INFORMATION List of Required Circuit Cards PN-M03 (M03) Location of Lamps, Switches and Connectors V35 JP1A JP1BRS OPE SD RD CD ER DR CS SELX21 To PN-2DPCB To V.35 DTE/DCE SELCN0 X21 CN0 SW0 OPRS OPER OPSD
Page 99
CHAPTER 5 CIRCUIT CARD INFORMATION List of Required Circuit Cards NEAX2000 IVS2 Data Interface System Manual ND-70924 (E), Issue 1.0 Page 93 Lamp Indications LAMP NAMECOLOR FUNCTION OPE Green ON: This card is normally connected to the PN-2DPCB. OFF: This card is abnormally connected to the PN-2DPCB. RS Green ON: RTS signal is ON. OFF: RTS signal is OFF. SD Green ON: TXD signal is “0” (Space condition). OFF: TXD signal is “1” (Mark condition). RD Green ON: RXD signal is “0” (Space condition)....
Page 100
NEAX2000 IVS2 Data Interface System ManualPage 94 ND-70924 (E), Issue 1.0 CHAPTER 5 CIRCUIT CARD INFORMATION List of Required Circuit Cards Switch Settings The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. NOTE:The JP1A and JP1B must be set to the same position each other. SWITCH NAMESWITCH...