Page 41
Page 41 SENSOR The horizontal axis of the graph shows the portion of the Frame Assembly that the sensor has detected. The green portion of the graph is the active area that the game uses during game mode, and the grey area is ignored by the game. The vertical axis of the graph represents the photo acceptance of the sensor. The horizontal green line in the middle of the graph is the OK/FAIL level. “O.K.” will be displayed if the level is above the green line. Adjust the sensors for the highest levels...
Page 42
Page 42 There are two adjustment screws in the Sensor Assy and these make adjustments to a pair of sensors together. The angle of the sensor can be changed by approx. ±2º by turning each adjustment screw (approx ±5.7mm). Adjustment Slacken slightly 2off cap screws under the sensor bracket, so that the sensor assembly can move by turning the adjustment screws. Note: If the screws are slackened too much, there will be too much movement of the sensor bracket, and adjustment cannot be made correctly. After...
Page 43
Page 43 Example Horizontal Adjustment Although the rear sensor is normal, the front sensor is showing a a low level in the left hand half of the graph. Turn the horizontal adjustment screw to raise the level of the graph. Although the rear sensor is normal, the front sensor is showing a a low level in the right hand half of the graph. Turn the vertical adjustment screw to raise the level of the graph. Due to the relationship between the performance of the reflective tape and the form of the frame, there...
Page 44
Page 44 6. ADJUSTMENTS Adjustment or maintenance on this machine should be carried out by qualified personnel only. Einstellungen und Wartung des Gerätes dürfen nur von dafür qualifiziertem Fachpersonal vorgenommen werden. Justeringer eller vedligehold af denne maskine bør kun udføres af kvalificeret personale. Los ajustes y el mantenimiento de esta máquina deben ser realizados sólo por personal cualificado. L’installation, le service, le réglage, ou la maintenance...
Page 45
Page 45 6-1 Adjustment Switches The Adjustment switches are located inside the coin door. 1. Service Switch. Press this switch to obtain game credits without incrementing the play meter. 2. Test Switch Slide the test switch ON to enter test mode. Test mode allows testing and the changing of game settings. (Refer to section 6-2 Test Mode page 46) 3. Select Up/Down Switch This switch is used to select the test required when in the Test Mode. 4. Enter Switch This switch is used to enter a selected test and...
Page 46
Page 46 6-2 Test Mode 1. Open the coin door and slide the test switch “ON”. The “Menu Screen” will be displayed on the monitor. 2. Select the test required by using the select up/down switch. The colour of the selected test will change. 3. Activate the test by pressing the Enter switch. Select “EXIT” in each test to return to the “Menu Screen”. 4. After testing is completed, slide the test switch to the “OFF” position to return to normal game mode. The Test Switch must always be in the “OFF” position for...
Page 47
Page 47 6-2-1 Coin Options 1. Select “COIN OPTIONS” on the menu screen to set the game cost and related settings. The following screen is displayed. 2. Use the Select Up/Down switch to choose the required item then press the Enter button. 3. Use the Select Up/Down switch to change the setting. 4. Press the Enter button to return to option select mode. 5. Select “EXIT” and press the Enter button to return to the menu screen. Note:- The price of play on this machine is set within the Cashflow Coin Mech....
Page 48
Page 48 6-2-2 Game Options 1. Select “GAME OPTIONS” on the menu screen to set the game variables, the following screen is displayed. 2. Use the Select Up/Down switch to choose the required item then press the Enter button. 3. Use the Select Up/Down switch to change the setting. 4. Press the Enter button to return to option select mode. 5. Select “EXIT” and press the Enter button to return to the menu screen. GAME OPTIONS [DEFAULT IN GREEN] LINK OFF GAME DIFFICULTY C(MEDIUM) (a) OFFICIAL RANKING...
Page 49
Page 49 (*1) The DIFFICULTY level changes the amount the player’s life gauge decreases when hit. (*2) When option (b) is set OFF, the internet link status and password are not displayed. When the DIFFICULTY level is changed from the default setting, this option is automatically set to OFF. This option can only be set ON if the DIFFICULTY setting is set to the default setting (C (MEDIUM)) (*3) The ranking delection screen is used to delete the high score player rankings displayed during the attract mode....
Page 50
Page 50 I/O TEST I/O PCB CHECK (6-2-3-1) SENSOR LEVEL CHECK (6-2-3-2) SWORD TEST (6-2-3-3) SWORD ADJUSTMENT (6-2-3-4) SWITCH TEST (6-2-3-5) LAMP TEST (6-2-3-6) SELECT SW : CHOOSE ENTER SW : ENTER 6-2-3 I/O Test 1. Select “I/O TEST” on the menu screen to test the sensors and switches. The following screen is displayed. 2. Use the Select Up/Down switch to choose the required item then press the Enter button. 6-2-3-1 I/O PCB Check 1. Select I/O PCB CHECK and press the Enter button. The...