Page 381
Peripheral Equipment Troubleshooting Procedures EACH NO RELAY CONTACT MAY BE USED TO CONTROL ‘A DEVICE, AS REQUIRED. 1 RELAY MODULE Y LJ NOTE 1: ALL WIRING MUST BE DONE IN ACCORDANCE WITH THE NATIONAL NOTE 5: THE SUPERCONSOLE 7OOOAlTENDANT ELECTRICAL CODE (USA) OR CANADIAN ELECTRICAL CODE AND/OR CONSOLE MAY CONNECT TO ANY PORT ON A LOCAL ELECTRICAL INSPECTION AUTHORITIES. DIGITAL LINE CARD. THE DIGITAL LINE CARD MUST BE IN A HIGH NOTE 2: CROSS-CONNECT FIELD PIN NUMBERS FOR EACH MODULE DEPEND...
Page 382
Troubleshooting Note: 1. Useful maintenance commands: SHOW STATUS, TEST, SHOW ALARMS, SHOW ERRORS CONSOLE - see the IX-232 Maintenance Terminal Practice. 2. Loop resistance should not exceed 200 ohms. Voltage across Tip and Ring should be between 40 and 48 volts dc. Table 3-13 SUPERCOIVSOLE 7000 Troubleshooting Procedures Step Possible Malfunction Source 1. No connection between the SUPERCONSOLE 7000 attendant console and a Digital Line Card circuit. 2. Faulty connections between the console...
Page 383
Peripheral Equipment Troubleshooting Procedures HANDSET LIQUID CRYSTAL DlSPlAY 10 DISPLAY ASSOCIATIVE KEYS (SOFTKEYS) . ...” . . . ..-.. .“-- [Fl> [FZ> [FE+ [F7> [~6>= [F7>0 [F8> 0 [F9>0 (FO’ Volye Vokme Co@ast Cy-@xt Ill, Telephone Number Func T!!! m-mm nk P Cancel Release I , ’ ’ “‘0~00000 Page PBlock i%old 4+ rHoId 3 loHold 2 \‘Hold 1 ]%swer ‘I/ I- 7 LED 14 ATTENDANT CONSOLE 12 DIAL KEYS INDICATORS KEYS (FIXED KEYS) 2 VOLUME CONTROL KEYS 2 CONTRAST CONTROL KEYS 4 CURSOR CONTROL...
Page 384
Troubleshooting Table 3-14 Attendant Console Error Indications indication HOLD 7 indicator flashing (after reset) HOLD 2 indicator flashing (after reset) HOLD 3 indicator flashing (after reset) All indicators on always (after reset) message: CONSOLE HARDWARE PROBLEM 123456789 ERROR CODE 1 Meaning Console fault - replace console. y Console fault - replace console. Console fault - replace console. Console fault - replace console. Console fault - replace console. message: WAITING FOR...
Page 385
Peripheral Equipment Troubleshooting Procedures SUPERSET 401+, and SUPERSET 410 Telephones The following table outlines, in descending order, the most likely items to cause malfunction. Table 3-l 5 SUPERSET 407+, and SUPERSET 410 Telephone Troubleshooting Procedures Item Possible Malfunction Source 1. Faulty connections between the set and the cross-connect field. 2. Faulty connections between the cross-connect field and the system. 3. Faulty CDE programming; likely forms: l COS Define l...
Page 386
Troubleshootingj Table 3-16 SUPERSET 420 and SUPERSET 430 Telephone Troubleshooting Procedures (continued) Item Possible Malfunction Source 3. Faulty CDE programming; likely forms: l COS Define l Stations 1 SUPERSETTelephones l Device Interconnection Table l System Configuration. 4. Set requires reset - disconnect, reconnect line cord. 5. Faulty SUPERSET telephone set or handset/cord assembly. 6. Digital Line Card requires re-initialization (reseat card). 7. Bay Control Card / Main Control...
Page 387
Peripheral Equipment Troubleshooting Procedures Step 4. 5. 6. 7. l3. 9. 10. Il. 12. 13. Table 3-17 DATASET 1103 / DATASET 2103 - DTE Mode Troubleshooting Procedures (continued) Possible Malfunction Source Faulty CDE programming; likely forms: l COS Define l Stations / SWE%X~Telephones l Data Circuit Descriptor l Data Assignment l DTE Profile l Device Interconnection Table l System Configuration. Incorrect DATASET 2103 switch settings - see Table 3-l 8 through Table 3-23. Faulty far...
Page 388
Troubleshooting Table 3-18 DATASET 2100 Switch Settings (Mode Selection) I I Switch No. Position Meaning 1 Down Set - PBX operation tJP Hunt - Back to back mode 2 tJP Synchronous Operation Down Asynchronous Operation Note: The DATASET should be in the SET mode when connected to the system. Table 3-l 9 DATASET 2100 Switch Settings (Asynchronous Flow Control) Asynchronous Flow Switch No. Control Type 3 4 Flow control disabled Down Down XON/XOFF flow control Down UP CTS flow control UP Down...
Page 389
Peripheral Equipment Troubleshooting Procedures Table 3-21 DATASET 2100 Switch Settings I (Sync Operating Mode Selection) Meaning Transparent mode X.31 mode Table 3-22 DATASET 2100 Switch Settings (Synchronous Clock Source) Internal clock System clock TX external clock TX and Rx external clock Down Down “P “P Down “P Down “P Table 3-23 D3TASET 2100 Switch Settings (Sync Speed) Synchronous Speed Switch No. 6 7 6 1200 Down 2400 “P 4800 Down 9600 “P 19200 X Down Down “P “P X...
Page 390
Troubleshooting , RS-232 PHONE MODE LINE CONNECTOR JACK SWITCHES POWER JACK piiiiik#diq POWER LED ASYNC READY DEVICE AlTENTlON DISCONNECT LED LED LED KEY KEY BBO047 Figure 3-8 DATASET 2103 Indicators and Connectors Table 3-24 DATASET 2103 LED indicators Indicator DEVICE Meaning ON - Indicates that the attached device is connected to the Dataset, and is supplying DSR or DTR on pin 21 of the RS-232 connector. FLASHING - Indicates that the Dataset is transmitting data OFF - Indicates that...