Troubleshooting - 9
Player Control Troubleshooting, 
continued
SYMPTOM CAUSE REQUIRED ACTION
Blocked or faulty fan Fan located on power supply functions as an
exhaust fan. With power on, check airflow near
each fan to assure that nothing blocks airflow.
Faulty mechanical
partsTurn off power. Open dashboard. Support
steering wheel and remove outer mounting
screws. Remove metal shield (if VGM has one)
over motor. Inspect for faulty or worn belts,
bearings, couplings, gears, etc.
Faulty Wheel Driver
Board1....

Page 112

Troubleshooting - 10
 BELT
TENSION BOLT
MOUNTING NUT
LOOSEN 
MOUNTING 
NUTS TO 
ADJUST BELT 
TENSION
How to Adjust Belt Tightness
Player Panel Controls 

Page 113

Troubleshooting - 11
Video Troubleshooting Table
SYMPTOM CAUSE REQUIRED ACTION
Power problem Verify connection of AC Power to video monitor.
Inspect neck of CRT in dim light. Glowing
filament near CRT base confirms monitor circuits
receive power. However, voltages or signals may
not be normal
.
Faulty wiring 1.  Turn off game power. Verify that video signal and
Remote Adjustment Board connectors seat
properly on Video Monitor Board.
2.  Assure that no wires are caught on chassis or
mounting brackets....

Page 114

Troubleshooting - 12
CAUTION
Do not remove or install any connector when power is turned on. Installation under
power will damage the circuit boards or ROM’s and void the warranty.
WARNING: HIGH VOLTAGE.
Video Game Machine (VGM) monitors 
generate and store potentially lethal high
voltages. 
Avoid touching any part of the monitor until power has been off for some time.
A picture tube can maintain a hazardous charge for up to several days. Only qualified
technicians should service monitors. Turn off the...

Page 115

Troubleshooting - 13
Video Troubleshooting, continued
SYMPTOM CAUSE REQUIRED ACTION
•  White areas at screen edges
appear tinged with color
•  Dots at screen edges appear
ovoid or cylindricalPicture tube dynamic
convergence is out of
alignmentHave service bureau dynamically re-converge
monitor. This procedure requires removing and
repositioning yoke. Service bureau must follow
instructions from monitor manufacturer.
Faulty wiring1. Check connectors and cables for wiring
continuity. Video cables connect...

Page 116

Troubleshooting - 14
Video Troubleshooting, continued
SYMPTOM CAUSE REQUIRED ACTION
•  Picture is too narrowMaladjusted WIDTH
potFrom Diagnostic Menu select MONITOR TEST.
Watch Crosshatch Screen while adjusting
WIDTH pot for best picture. You’ll find this pot on
Monitor Remote Control Board, behind coin door.
•  Picture is too shortMaladjusted HEIGHT
pot or damaged
vertical circuit1.  From Diagnostic Menu select MONITOR TEST.
Watch Crosshatch Screen while adjusting
HEIGHT pot for best picture. You’ll...

Page 117

Troubleshooting - 15
Audio Troubleshooting Table
SYMPTOM CAUSE REQUIRED ACTION
Improper volume
settingPress and hold TEST MODE switch inside coin
door to enter Menu System. Select VOLUME
MENU from the Main Menu. Make sure the
Attract Music is on (enabled). Verify all volume
levels are set well above zero. If necessary,
change levels to make game audible.
Faulty wiringTurn off power. Assure wiring harness
connectors attach and fully seat onto mating
board connectors. Verify harness connects to
CPU Board....

Page 118

Troubleshooting - 16
Audio Problems, continued
SYMPTOM CAUSE REQUIRED ACTION
Faulty speaker 1.  From Diagnostics Menu, choose SOUND TEST.
Recheck speakers with audio signals provided
by test.
2.  Verify proper speaker operation by connecting
speaker in question to working Video Game
Machine (VGM).•  Dead sound channel
Faulty circuit board Run power-up self-test sequence. Note errors
found during tests. Compare CPU Board LED’s
with LED Indicator Status Charts. Note
discrepancies.
Faulty wiring 1.  Check...

Page 119

Troubleshooting - 17
 Motion Seat Troubleshooting
SYMPTOM CAUSE REQUIRED ACTION
Power Problem1.  Turn on Power. Use 20-volt DC setting on digital
voltmeter to measure DC voltages present at
Power connector pins. Verify +5V source if it is
adjustable. Refer to Cabinet Wiring Diagram for
specific wiring information and voltage limits.
2. Use 2-Volt AC setting on digital voltmeter to
measure DC voltages at Power Connector pins.
Any reading indicates the supply voltages are
unstable and may contain ripple or...

Page 120

Troubleshooting - 18
Miscellaneous Problem Troubleshooting Table
SYMPTOM CAUSE REQUIRED ACTION
Faulty fluorescent
tube1.  Remove fluorescent tube from sockets. If you
find cracks or darkened ends, install new lamp.
Clean tube.
2.  Check continuity of both fluorescent tube
filaments.
3.  Check lamp ballast is rated for local AC line
voltage and frequency.
4.  Verify fluorescent tube operates by placing it in
working VGM.
Faulty lamp fixture 1.
2.Verify lamp pins make good connection with
socket contacts....