Home > Hughes JVC > Projector > Hughes JVC Projector 230 Service Manual

Hughes JVC Projector 230 Service Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Hughes JVC Projector 230 Service Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 14 Hughes JVC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							Chapter 4---Maintenance (Removal/Replacement)
    Model 230 Service Manual4-15
    Figure 4-11.   Horizontal/Vertical Deflection PCB.
    4.12   Video Input Cards (VICs)
    Instructions for installing, removing, editing and VIC Settings are covered in
    Chapter 5 of the Model 230 Users Guide.
    4.13   Video Amplifier PCB
    The Video Amplifier PCB for the 3 CRTs is located under the Electronic Module,
    on the bottom frame of the projector behind and under the CRT assemblies.
    To remove a Video Amplifier PCB:
    1.   Remove the front and rear covers (Section 4.2).
    2.   Tilt the Electronic Module up (Section 3.2).
    3.   Loosen the Green CRT Holder Ring (knurled knob-see Figure 3-8). Read the
    Caution below this step before removing the CRT Holder Ring completely.
    NOTE: The holder ring should only be hand-tight. If it cannot be removed by
    hand, a flathead screwdriver can be used in the slots on the CRT Holder
    Ring (Figure 3-8) to help loosen it. Be careful not to let the flathead
    screwdriver slip out of the slot and possibly damage components. Do not use
    a screwdriver or any other tool to tighten this ring-it should be hand-tight only.
     CAUTION! This step is performed with the CRT Socket
    Connector still connected to the Green CRT and the ground wire still connected
    from the CRT/Yoke Assembly to the CRT Socket Connector. This is because the
    Green CRT Socket Connector is close to the rear of the projector and is easier
    to disconnect from the CRT after the CRT/Yoke Assembly is loose and is moved 
    						
    							Chapter 4---Maintenance (Removal/Replacement)
    4-16Model 230 Service Manual
    away from the rear of the projector. Use extreme care not to break any of these
    connections when removing the CRT/Yoke Assembly.
    4.   Carefully remove the Green CRT/Yoke Assembly by sliding it backward and
    upward as far as possible before disconnecting the Green CRT Socket
    Connector from the CRT neck. Use care to avoid bumping the CRT as it is
    being removed and to avoid breaking any of the wires that connect from the
    CRT Socket Connector to the Video Amplifier.
    5.   Move the Green CRT/Yoke Assembly away from the rear of the projector,
    then disconnect the Green CRT Socket Connector and the ground wire
    between the CRT/Yoke Assembly and the CRT Socket Connector. NOTE: It
    may be helpful to perform this step with a partner-one person to hold the
    CRT/Yoke Assembly firmly and the other to remove the CRT Socket
    Connector and the ground wire.
    6.   Gently lay the Green CRT Socket Connector on the top of the Video
    Amplifier PCB.
    7.   Place the Green CRT Assembly in a safe location on or against one of the
    other CRT Assemblies.
    8.   Disconnect the Red and Blue CRT Socket Connectors and gently lay them
    on the top of the Video Amplifier Board.
    9.   Disconnect the 3 connectors (push in slightly, squeeze the tabs, and pull
    out), J67, J68, and J69 from the Video Amplifier PCB )Figure 4-12). Move the
    cables out of the way.
    Figure 4-12.   Video Amplifier PCB showing breakaway CRT Socket
    Connectors. 
    						
    							Chapter 4---Maintenance (Removal/Replacement)
    Model 230 Service Manual4-17
    10. Disconnect the 3 Focus cables that run from the CRT Socket Connectors to
    the Focus connectors on the HVPS. NOTE: Observe that each of the 3
    Focus cables (large, red wires that run from each CRT Socket Connector to
    the Focus connectors on the HVPS) is joined near the CRT by a coupler plug
    and jack. Disconnect (and label) the focus cables at these couplers.
    11. Loosen the 6 pozidrive screws that secure the Video Amplifier PCB to the
    projector frame.
    12. Make sure everything is out of the way, then slide the Video Amplifier PCB
    toward the left so the mounting screws will clear the access holes and
    remove the board from the projector.
    13. Reinstall in the reverse order from above. NOTE: The Video Amplifier PCB is
    shipped with the 3 CRT Socket Connectors attached at the end in a
    “breakaway” arrangement (Figure 4-12). Use a pair of diagonal cutters and
    carefully cut the socket connectors away from the Video Amplifier PCB. The
    spacers between the CRT Socket Connectors can be discarded.
    4.14   Scan Reversal PCB
    The Scan Reversal PCB is located on the right side of the Electronic Module.
    To remove the Scan Reversal PCB:
    1.   Remove the projector rear cover.
    Figure 4-13.   Scan Reversal PCB.
    2.   Disconnect 7 connectors (Figure 4-13); J52, J54, J64, J65, J66, J50 (or
    J50A), and J100 (or J101). To remove, push in slightly, squeeze the tabs,
    then pull connector out.
    3.   Move all cables out of the way. 
    						
    							Chapter 4---Maintenance (Removal/Replacement)
    4-18Model 230 Service Manual
    4.   Remove the 4 pozidrive screws (Figure 4-13) and lift the board out.
    5.   Reinstall in the reverse order from above.
    4.15   CRT/Yoke Assembly
     WARNING!!! The CRT/Yoke Assemblies should be handled with
    extreme caution. If dropped they can implode and flying glass can cause severe
    injury to personnel. Be careful not to bump or drop the CRT. Place in a safe area
    immediately after removal.
    Three CRT/Yoke Assemblies are located in the CRT Assembly area below the
    card cage. To remove a CRT/Yoke Assembly (refer to Figure 4-14):
    Figure 4-14.   View of CRTs, Relay lenses and 
    ILA® Assemblies.
    1.   Remove front and rear covers (Section 4.2).
    2.   Tilt the Electronic Module up and lock it in place (Section 3-2).
    3.   Remove the two pozidrive screws from the top of the High Voltage Power
    Supply (HVPS) cover (Figure 4-7) and remove the one screw at the bottom
    of the cover and loosen the two screws at the top of the cover.
    4.   Remove the CRT anode cable (for the CRT that is to be replaced) from the
    HVPS.
    5.   Disconnect the Yoke plug and cable harness from the Scan Reversal PCB
    for the appropriate CRT (see Figure 4-13). 
    						
    							Chapter 4---Maintenance (Removal/Replacement)
    Model 230 Service Manual4-19
    6.   Remove the wires from the cable clamp for the CRT/Yoke Assembly that is
    being removed.
    7.   Loosen the CRT Holder Ring (knurled knob in Figure 3-8). NOTE: The CRT
    Holder Ring should be only hand-tight. If it cannot be removed by hand only,
    a flathead screwdriver can be used in the slots on the CRT Holder Ring to
    help loosen it. Do not use a tool of any kind to tighten this ring-it should be
    hand tight only.
    8. 
     CAUTION! For the Green CRT/Yoke Assembly only, this
    step is best performed with the Green CRT still connected to the CRT socket
    connector and the ground wire still connected from the CRT to the socket
    connector. This is because the Green socket connector is close to the rear of
    the projector and is easier to disconnect from the CRT after the CRT/Yoke
    Assembly is loose and is moved away from the rear. Be careful not to break
    any of these connections.
    Gently remove the CRT/Yoke Assembly by sliding it backward and upward
    as far as possible before unplugging the CRT socket connector from the
    neck. Use caution to avoid bumping the CRT/Yoke Assembly as it is being
    removed.
    9.   After removing the CRT/Yoke Assembly, carefully unplug the CRT socket
    connector and the ground wire that connects the CRT to the socket
    connector. NOTE: It may be helpful to have another person assisting for step
    9. One person can unplug the CRT socket connector and ground wire, while
    the other person holds the CRT/Yoke Assembly firmly.
    10. After verifying that all cables are out of the way, remove the CRT/Yoke
    Assembly from the projector.
    11. Reinstall the CRT/Yoke Assembly in the reverse order. NOTE: When
    reinstalling the CRT/Yoke Assembly, plug the CRT ground wire into the CRT
    Socket Connector first, then partially plug in the Green socket connector into
    the CRT. When the CRT is completely installed it will be easier to fully insert
    the CRT into the socket connector.
    12. Perform a CRT Mechanical focus adjustment (Section 3.4) and CRT Rotation
    (Section 3.5) after replacing the CRT/Yoke Assembly. Check the CRT
    Mechanical Focus on the other two colors to verify that they are still correct.
    It is possible the other focus adjustments could have been disturbed by the
    removal and replacement of the CRT/Yoke Assembly.
    4.16   ILA® 
    Assembly
    To remove an ILA® Assembly:
    1.   Remove the rear cover (Section 4.2).
    2.   Tilt up the Electronic Module (Section 3-2). 
    						
    							Chapter 4---Maintenance (Removal/Replacement)
    4-20Model 230 Service Manual
    3.   Disconnect the connector on the top of the appropriate ILA® assembly.
    (Figure 4-14).
    Figure 4-15.  ILA® Assembly top view. The overlap screws shown are
    visible after the 
    ILA® assembly is removed.
    4.   Loosen the two wingnuts at the top of the appropriate ILA® assembly (Figure
    4-15).
    5.   Slide the spring clip at the top of the ILA
    ® assembly backward (Figure 4-15).
    This will free the ILA® assembly.
    6.   Grasp the ILA
    ®  assembly by its housing and slide it out.
    7.   Replace the ILA
    ® in the reverse order from above.
    8.   Recheck the ILA
    ® Back Focus (Section 3.3) and the ILA® Overlap
    adjustment (Section 3.7).
    9.   Recheck convergence, shading, ILA
    ® bias and G2 and readjust, if necessary
    (User’s Guide, Chapter 5).
    4.17   Relay Lens
    To remove a Relay Lens (refer to Figure 4-14):
    1.   Remove the rear cover (Section 4.2).
    2.   Tilt up the Electronic Module (Section 3.2)
    3.   Remove the corresponding CRT Assembly behind the Relay Lens that is to
    be removed (refer to Section 4.15). 
    						
    							Chapter 4---Maintenance (Removal/Replacement)
    Model 230 Service Manual4-21
    4.   Loosen the CRT Lens Stopper Ring (the thin collar just in front of the CRT
    Holder knurled ring-Figure 4-14) and slide it off the back of the Relay Lens.
    5.   Loosen the wing nut on top of the Relay Lens mount (the bracket at the rear
    of the Relay Lens).
    6.   Remove the 2 long hex bolts at the front of the Relay Lens (shown in Figure
    4-15).
    7.   Remove the 2 hex bolts at the rear of the Relay Lens (these bolts are level
    with the bottom of the Relay Lens and hold the bracket in place).
    8.   Remove the Relay Lens. Leave the Relay Lens Bracket and the CRT Lens
    Stopper Ring in the projector-do not send them back with the Relay Lens.
    9.   Replace the Relay Lens in reverse order from above.
    4.18   Projection Lens
    To remove the Projection Lens:
    1.   Remove the sponge cover from around the front of the Projection Lens.
    2.   Disconnect and label the Projection Lens Focus and Zoom motor cables
    (The Focus motor is at the top of the Projection Lens. The Zoom motor is at
    the bottom.)
    3.   Loosen (do not remove) the Lens holding screw at the right side (Figure 4-
    16) of the Projection Lens.
    4.   Rotate the Projection Lens left or right so that the notch on the lens clears
    the holding screw on the lens holder (Figure 4-16). 
     CAUTION!
    The lens can fall out now! Carefully slide the lens out.
    Figure 4-16.   Projection Lens holding screw and removal notch.
    5.   Replace the Projection Lens in reverse order. NOTE: The same basic
    procedure above is used to install or remove optional fixed lenses.
    NOTE: When changing from a zoom to a fixed lens, or vice versa, the ILA
    ® Back
    Focus (Section 3.3) may need readjustment. 
    						
    							Chapter 4---Maintenance (Removal/Replacement)
    4-22Model 230 Service Manual
    4.19   Prism Assembly
     CAUTION! The removal of the Prism Assembly requires
    removing the Dichroic Mirror Assembly (X-Plate). In most cases this necessitates
    an optical realignment. HJT does not recommend performing this
    replacement in the field. Optical alignment is critical and requires projector
    power to be on. This results in an additional safety hazard due to the high
    intensity light beam emanating from the optical area with the optical cover off. If
    removal and replacement is absolutely necessary, proceed with extreme caution
    and wear proper safety glasses as outlined in the section on safety at the front of
    this manual.
    The Prism Assembly requires removing more components and assemblies than
    any other assembly. Be sure to have storage cabinets or tables to house the
    items as they are removed to provide access to the Prism Assembly. Allow 2-4
    hours to perform the removal and replacement of the Prism Assembly. Refer to
    Figures 4-1 and 4-14 for assemblies referenced in this procedure.
    To remove the Prism Assembly:
    1.   Remove front and rear covers (Section 4.2).
    2.   Remove the Dichroic Shield (3 screws).
    3.   Remove the lower right side panel (5 screws).
    4.   Remove the Arc Lamp Assembly (Section 4.4).
    5.   Remove the Ignitor Assembly (Section 4.5).
    5.   Remove the Dichroic Mirror assembly by removing the remaining hex bolts
    (Figure 4-17). Use care when lifting the mirror assembly. Place it in a safe,
    level storage area.
    6.   Remove the 2 hex bolts from the front of the Prism assembly (Figure 4-17).
    7.   Remove the Rollbar assembly (2 pozidrive bolts/nuts on left side and two
    nuts on right side). Disconnect and label the 2 connectors on the hinge
    assembly for the shutter motors (1 in front and 1 in rear). Remove and label
    the jumper that connects the front interlock switch to the rear interlock switch.
    8.   Remove the Rollbar Bracket that was holding up the left side of the Rollbar
    assembly.
    9.   Remove the 3 ILA
    ® asssemblies (Section 4.16). 
    						
    							Chapter 4---Maintenance (Removal/Replacement)
    Model 230 Service Manual4-23
    Figure 4-17.   Dichroic Mirror Assembly.
    Figure 4-18.   Prism Assembly mount. 
    						
    							Chapter 4---Maintenance (Removal/Replacement)
    4-24Model 230 Service Manual
    10. Remove the remaining three hex bolts from the rear of the Prism assembly.
    These screws are located in the cavities where the ILA® assemblies were
    removed.
    11. The Prism is now free to be removed.
     CAUTION! The Prism assembly is heavy (about 70 lbs).
    Use two people to lift it out of the projector.
    12. Replace the Prism assembly in the reverse order.
    4-20   Recommended Spares
    It may be advisable to maintain a supply of spares for the projector to maximize
    performance. This is particularly important when projectors are being operated
    on a continuous basis or when multiple projectors are needed. Table 4-1, below,
    provides a list of the spares that HJT recommends for one to four projectors.
    Table 4-1.   Recommended minimum spares
    PART NO. DESCRIPTION QUANTITY
    102583 PCA Horiz/Vert Deflection 1
    102581 PCA Conv/Defl 1
    105232 PCA Video Amplifier 1
    105234 PCA Video Processor 1
    104678 PCA System Controller 1
    102589 PCA Raster Timing Gen. 1
    102585 PCA Scan Reversal 1
    104413 PCA Graphics Enhancer VIC 1
    102520 System Power Supply 1
    102566 High Voltage Power Supply 1
    104787 Arc Lamp Module 1-4 
    						
    All Hughes JVC manuals Comments (0)

    Related Manuals for Hughes JVC Projector 230 Service Manual