    							HP A5500 EI & A5500 SI Switch Series 
    Installation Guide 
    Abstract 
    This document guides you through installation of HP A Series products, including installing the device, 
    connecting to the network, hardware  management, and troubleshooting. 
    Part number: 5998-1710  
    Document version: 6W100-20110730
     
      
    						
    							Legal and notice information 
    © Copyright 2011 Hewlett-Packard Development Company, L.P. 
    No part of this documentation may be reproduced or transmitted in any form or by any means without 
    prior written consent of Hewlett-Packard Development Company, L.P. 
    The information contained herein is  subject to change without notice.  
    HEWLETT-PACKARD COMPANY MAKES NO WARRANTY OF ANY KIND WITH REGARD TO THIS 
    MATERIAL, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY 
    AND FITNESS FOR A PARTICULAR PURPOSE. Hewlett-Pa ckard shall not be liable for errors contained 
    herein or for incidental or consequential damages in  connection with the furnishing, performance, or 
    use of this material.  
    The only warranties for HP products and services  are set forth in the express warranty statements 
    accompanying such products and se rvices. Nothing herein should be construed as constituting an 
    additional warranty. HP shall not be liable for tech nical or editorial errors or omissions contained 
    herein. 
    						
    							iii  
    Contents 
    Preparing for in stallation ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ·········· ··················\
    ··················\
    ····· 1 
    Safety recommendations ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ·············· ··················\
    ··················\
    ······ 2 
    Installation site requirements ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ······ ··················\
    ················· 2 
    Rack-mounting requirements  ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ······  3 
    Installation tools ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ···················\
    ················  3 
    Installing the switch ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ·································\
    ··················\
    ········· 4 
    Installing the switch in a 19-inch rack ··················\
    ··················\
    ··················\
    ··················\
    ··············· ··················\
    ··················\
    · 6 
    Mounting brackets ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ···················\
    ···  7 
    Rack-mounting by using only front mounting brackets ··················\
    ··················\
    ··················\
    ··················\
    ··· ·············· 8 
    Rack-mounting by using front mounting brackets and a rack shelf  ··················\
    ··················\
    ··················\
    ············ 10 
    Rack-mounting by using front and rear mounting  brackets ··················\
    ··················\
    ··················\
    ················· ······· 10 
    Mounting the switch on a workbench  ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ··············  15 
    Grounding the switch ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ················ ··················\
    ··················\
    ······ 15 
    Grounding the switch with a grounding strip ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ···········  15 
    Grounding the switch with a grounding conductor buried in the earth ground··················\
    ··················\
    ·········  17 
    Grounding the switch by using the AC power cord ··················\
    ··················\
    ··················\
    ··················\
    ··················\
      18 
    Installing/removing a power supply ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ·· ··················\
    ·············· 19 
    Installing a power supply ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ··········· ··················\
    ·············· 19 
    Removing a power supply  ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ······  20 
    Connecting the power cord ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ··········· ··················\
    ··················\
    · 21 
    Connecting the AC power cord  ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ···············  21 
    Connecting the PSR150-D to a –48 VDC power source ··················\
    ··················\
    ··················\
    ··················\
    ····· ····· 22 
    Connecting the switch to  a +12 VDC output RPS ··················\
    ··················\
    ··················\
    ··················\
    ········· ············· 23 
    Connecting the switch to a  –52 to –55 VDC output RPS ··················\
    ··················\
    ··················\
    ··················\
    ·· ········ 24 
    Installing/removing an  interface card ··················\
    ··················\
    ··················\
    ··················\
    ················· ··················\
    ·············· 24 
    Installing an interface card  ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ·····  25 
    Removing an interface card ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ·········· ··················\
    ··········· 26 
    Installing/removing a dedi cated CX4/SFP+ cable ··················\
    ··················\
    ··················\
    ··················\
    ········ ··········· 26 
    Verifying the in stallation ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ·········· ··················\
    ··················\
    ········ 27 
    Accessing the switch for the first time ··················\
    ··················\
    ··················\
    ··················\
    ··············· ··················\
    ·············· 28 
    Setting up the config uration environment ··················\
    ··················\
    ··················\
    ··················\
    ·············· ··················\
    ············ 28 
    Connecting the console cable ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ········ ··················\
    ··················\
     28 
    Setting terminal parameters ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ········· ··················\
    ··················\
    ··· 29 
    Powering on the switch ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ·············· ··················\
    ··················\
    ····· 32 
    Changing the startup mode  ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ····  35 
    Setting up an IRF fabric ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ············ ··················\
    ··················\
    ··· 38 
    IRF fabric setup flowchart ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ·········· ··················\
    ··················\
    ······ 38 
    Planning IRF fabric setup ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ··········· ··················\
    ··················\
    ······ 39  
    						
    							iv  
    Planning IRF fabric size and the installation site  ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ······  39 
    Identifying the master switch and planning IRF member IDs ··················\
    ··················\
    ··················\
    ··············· ······· 39 
    Planning IRF topology  and connections ··················\
    ··················\
    ··················\
    ··················\
    ················· ··················\
    ··· 40 
    Identifying physical IRF port s on the member switches ··················\
    ··················\
    ··················\
    ··················\
    · ············ 41 
    Planning the cabling scheme ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ········· ··················\
    ·········· 41 
    Configuring basic IRF settings ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ······ ··················\
    ··················\
    ·· 42 
    Connecting the physical IRF ports ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ··· ··················\
    ················· 43 
    Accessing the IRF fabric to  verify the configuration ··················\
    ··················\
    ··················\
    ··················\
    ·· ··················\
    ······· 43 
    Maintenance and tr oubleshooting ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ····· ··················\
    ··········· 44 
    Password loss ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ····· ··················\
    ··················\
    ············ 44 
    Console login password loss ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ········· ··················\
    ·········· 44 
    Boot ROM passw ord loss ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ·············· ··················\
    ··········· 44 
    Power supply failure ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ················ ··················\
    ··················\
    ········ 44 
    Fixed power supply failure ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ·········· ··················\
    ············· 44 
    Hot swappable power supply failure ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ·· ··················\
    ···· 46 
    Fan failure ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ······· ··················\
    ··················\
    ················ 46 
    Configuration terminal problems  ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ····  46 
    Support and other resources ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ········· ··················\
    ················ 48 
    Contacting HP ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ····· ··················\
    ··················\
    ··········· 48 
    Subscription service ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ················ ··················\
    ··················\
     48 
    Related information ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ················· ··················\
    ··················\
    ········· 48 
    Documents ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ········· ··················\
    ··················\
    ····· 48 
    Websites ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ·········· ··················\
    ··················\
    ······ 48 
    Conventions ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ······· ··················\
    ··················\
    ············· 49 
    Appendix A Technical specifications ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    · ··················\
    ·········· 51 
    Physical specifications ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ············· ··················\
    ··················\
    ········ 51 
    Chassis dimensions and weights ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ······ ··················\
    ······· 51 
    Ports and interfac e card slots ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ······ ··················\
    ············· 51 
    Chassis panel views  ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ···················\
    ······  52 
    A5500-24G EI (2 slots)/A5500-24G EI TAA (2 slots)/A5500-24G SI (2 slots) panel views ··················\
    ···  52 
    A5500-48G EI (2 slots)/A5500-48G EI TAA (2 sl ots)/A5500-48G SI (2 slots) panel views ··················\
    ···  53 
    A5500-24G-SFP EI (2 slots)/A5500-24G-S FP EI TAA (2 slots) panel views ··················\
    ··················\
    ··············  54 
    A5500-24G-PoE+ EI (2 slots)/A5500-24G-PoE+ EI TAA (2 slots)/A5500-24G-PoE+ SI (2 slots)  
    panel views ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ······· ··················\
    ··················\
    ····· 55
     
    A5500-48G-PoE+ EI (2 slots)/A5500-48G-PoE+ EI TAA (2 slots)/A5500-48G-PoE+ SI (2 slots)  
    panel views ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ······· ··················\
    ··················\
    ····· 56
     
    Environmental specifications ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ········ ··················\
    ··················\
    ··· 57 
    Power specifications ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ················ ··················\
    ··················\
    ········ 57 
    Power input types ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    · ··················\
    ··················\
    · 57 
    AC input voltage specifications ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ····· ··················\
    ·········· 57 
    RPS DC input voltage specificat ions and RPS compatibility ··················\
    ··················\
    ··················\
    ··············· ········ 58 
    Power consumption specificatio ns for non-PoE switches ··················\
    ··················\
    ··················\
    ··················\
    · ·········· 58  
    						
    							v  
    Power consumption specificat ions for PoE switches ··················\
    ··················\
    ··················\
    ··················\
    ····· ············· 58 
    Cooling system ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ···· ··················\
    ··················\
    ··········· 59 
    Appendix B FRUs and compatibility matrixes ··················\
    ··················\
    ··················\
    ··················\
    ············ ··················\
    ···· 60 
    Hot swappable powe r supplies ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ········ ··················\
    ················ 60 
    Interface cards ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ··· ··················\
    ··················\
    ············· 61 
    SFP/SFP+/XFP transceiver modules and SFP+/CX4 cables ··················\
    ··················\
    ··················\
    ··················\
    ·· ··········· 61 
    GE SFP transceiver modules  ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ···  62 
    FE SFP transceiver modules ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ·········· ··················\
    ············ 63 
    10-GE SFP+ transceiver modules  ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ·············  63 
    SFP+ cables ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ···················\
    ···········  64 
    10-GE XFP transceiver modules ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ·························\
    ········ 65 
    CX4 cables ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ···················\
    ············  65 
    Appendix C Ports and LEDs ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ··········· ··················\
    ··············· 66 
    Ports ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ············· ··················\
    ··················\
    ··················\
    ·· 66 
    Console port ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ······ ··················\
    ··················\
    ···· 66 
    10/100/1000Base-T Ethernet port ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ····· ··················\
    ··· 66 
    SFP port ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ·········· ··················\
    ··················\
    ········ 66 
    Combo interface ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ···················\
    ···  67 
    LEDs ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ································\
    ··················\
    ··················\
    · 68 
    System status LED ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    · ··················\
    ··················\
    · 68 
    Power supply status LEDs ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ············ ··················\
    ·············· 69 
    RPS status LED ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ···· ··················\
    ··················\
    ···· 69 
    Port mode LED··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ······ ··················\
    ··················\
    ·· 70 
    Seven-segment LED ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ··················  70 
    10/100/1000Base-T Ethernet port LED ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ·  71 
    SFP port status LED ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ················· ··················\
    ··················\
    · 72 
    Interface card status LED  ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ·········  73 
    Index ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ··················\
    ·······························\
    ··················\
    ·············· 74 
     
     
      
    						
    							 1  
    Preparing for installation 
    The HP A5500 EI & A5500 SI Switch Series includes the models in   
    Table 1.  
    Table 1  Models in the 
    HP A5500 EI  & A5500 SI Switch Series 
    T
    ype  Product code  HP description Alias 
    Non-PoE JD377A 
    HP A5500-24G EI Switch with 2 
    Interface Slots 
    A5500-24G EI (2 slots) 
    JG250A HP A5500-24G EI TAA Switch with 2 
    Interface Slots 
    A5500-24G EI TAA(2 slots) 
    JD375A HP A5500-48G EI Switch with 2 
    Interface Slots 
    A5500-48G EI (2 slots) 
    JG251A HP A5500-48G EI TAA Switch with 2 
    Interface Slots 
    A5500-48G EI TAA (2 slots) 
    JD374A HP A5500-24G-SFP EI Switch with 2 
    Interface Slots 
    A5500-24G-SFP EI (2 slots) 
    JG249A HP A5500-24G-SFP EI TAA Switch with 
    2 Interface Slots  A5500-24G-SFP EI TAA (2 
    slots) 
    JD369A 
    HP A5500-24G SI Switch with 2 
    Interface Slots 
    A5500-24G SI (2 slots) 
    JD370A HP A5500-48G SI Switch with 2 
    Interface Slots 
    A5500-48G SI (2 slots) 
    PoE JG241A 
    HP A5500-24G-PoE+ EI Switch with 2 
    Interface Slots 
    A5500-24G-PoE+ EI (2 slots) 
    JG252A HP A5500-24G-PoE+ EI TAA Switch 
    with 2 Interface Slots  A5500-24G-PoE+ EI TAA (2 
    slots) 
    JG240A 
    HP A5500-48G-PoE+ EI Switch with 2 
    Interface Slots 
    A5500-48G-PoE+ EI (2 slots) 
    JG253A HP A5500-48G-PoE+ EI TAA Switch 
    with 2 Interface Slots  A5500-48G-PoE+ EI TAA (2 
    slots) 
    JG238A 
    HP A5500-24G-PoE+ SI Switch with 2 
    Interface Slots 
    A5500-24G-PoE+ SI (2 slots) 
    JG239A HP A5500-48G-PoE+ SI Switch with 2 
    Interface Slots 
    A5500-48G-PoE+ SI (2 slots) 
      
    						
    							 2  
    Safety recommendations  
     WARNING! 
    Before installation and operation, read all of the safety instructions i\
    n the 
    Compliance and Safety 
    Gui
    de supplied with your device.  
    This section provides general recommendations. For more information, see the  Compliance and Safety 
    Guide . 
    •   Turn off all power and remove all power  cables before opening the chassis. 
    •   Unplug all power and external cabl es before moving the chassis. 
    •   Locate the emergency power-off switch before in stallation and shut off power immediately if 
    necessary. 
    •   Always wear an ESD-preventive wris t strap when installing the device. 
    •   Do not stare into the open optical interface. Th e high-power density light can burn the retina. 
    •   Use a good grounding system to protect your ro uter against lightning shocks, interference, and 
    ESD. This is essential to the operating reliability of your switch. 
    •   Make sure that the resistance between the chassis and the ground is less than 1 ohm. 
    Installation site requirements   
    The following tables provide info rmation about temperature and humidity, cleanness, and air quality 
    requirements. 
    To ensure normal operation of the router, make sure  that the room temperature meets the requirements 
    described in  Table 2. 
    Table 2  Temperature r
    
    equirements 
    Tem
    perature Range 
    Operating 
    temperature  Long term: 0°C to 45°C (32°F to 113°F)  
    Short term: –10°C to +55°C (14°F to 131°F)
     (no more than 96 hours of continuous 
    operation in less than 15 days in one year) 
    Storage 
    temperature  –40°C to +70°C (–40°F to +158°F) 
     
     
    CAUTION: 
    If condensation appears on the router when you move
     it to a high-temperature environment, dry the 
    router before powering it on  to avoid short circuits.  
      
    						
    							 3  
    Maintain appropriate humidity in your equipment room, as described in  Table 3. 
    Table 3  Humidity requ
    irements 
    Humidit
    y Range
    Operating humidity (noncondensing) 5% to 95%
    Storage humidity (noncondensing)  5% to 95%
     
    Lasting high relative humidity tends to cause p oor insulation, increased electricity consumption, 
    mechanical property change of materials, and corrosion  of metal parts. Lasting low relative humidity is 
    likely to result in loose screws due to washer contract ion, and even ESD, which causes the circuits to fail. 
    Table 4  Dust concentration limit in the equipment room 
    Ph
    ysical active substance  Concentration limit (particles/m3)
    Dust particle  ≤3 x 104 (No visible dust on desk over three days)
    Note: Dust particle diameter ≥ 5 μm 
    Table 5  Limits on harmful gases in the equipment room 
    Gas Ma
    x concentration (mg/m3)
    SO2  0.2 
    H2S 0.06 
    NH3 0.05 
    Cl2  0.01 
     
    Rack-mounting requirements   
    Before rack-mounting a switch, make sure 
    the rack meets the following requirements: 
    •   HP recommends that the switch is mounted in an op en rack. If you mount a switch in a closed rack, 
    make sure there is a good heat dissipation system. 
    •   The rack is steady enough to support the switch and accessories. 
    •   The switch fits the rack size. Leave some space be side the left and right panels of the switch for 
    chassis heat dissipation. 
    Installation tools 
    •   Flathead screwdriver 
    •   Phillips screwdriver 
    •   Needle-nose pliers 
    •   Wire-stripping pliers 
    •   Diagonal pliers 
    •   ESD-preventive wrist strap 
    •   Blow dryer 
    All these installation tools are user supplied.  
    						
    							 4  
    Installing the switch 
     
      CAUTION: 
    Keep the tamper-proof seal on a mounting screw on 
    the chassis cover intact, and if you want to open 
    the chassis, contact HP for permission. Otherwise,  HP will not be liable for any consequence caused 
    thereby.  
    						
    							 5  
    Figure 1  Hardware installation flow 
    No
    Start
    Install the switch to a 
    19-in rack or workbench
    Ground the switch
    Install hot swappable  power supplies?
    Yes
    Install hot swappable power  supplies
    Connect the power cords
    Verify the installation
    Power on the switch
    Operating properly?Power off the switch
    Troubleshoot the 
    switch
    Install interface cards? Yes
    YesNo
    No
    Install interface cards
    Operating properly?
    Yes No
    Troubleshoot the 
    switch
    End
    Install transceiver modules, connectors, and cables
      
    						