HP 5500 Ei 5500 Si Switch Series Installation Guide
Have a look at the manual HP 5500 Ei 5500 Si Switch Series Installation Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1114 HP manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
HP A5500 EI & A5500 SI Switch Series Installation Guide Abstract This document guides you through installation of HP A Series products, including installing the device, connecting to the network, hardware management, and troubleshooting. Part number: 5998-1710 Document version: 6W100-20110730
Legal and notice information © Copyright 2011 Hewlett-Packard Development Company, L.P. No part of this documentation may be reproduced or transmitted in any form or by any means without prior written consent of Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. HEWLETT-PACKARD COMPANY MAKES NO WARRANTY OF ANY KIND WITH REGARD TO THIS MATERIAL, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Hewlett-Pa ckard shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and se rvices. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for tech nical or editorial errors or omissions contained herein.
iii Contents Preparing for in stallation ··················\ ··················\ ··················\ ··················\ ··················\ ·········· ··················\ ··················\ ····· 1 Safety recommendations ··················\ ··················\ ··················\ ··················\ ··················\ ·············· ··················\ ··················\ ······ 2 Installation site requirements ··················\ ··················\ ··················\ ··················\ ··················\ ······ ··················\ ················· 2 Rack-mounting requirements ··················\ ··················\ ··················\ ··················\ ··················\ ··················\ ··················\ ······ 3 Installation tools ··················\ ··················\ ··················\ ··················\ ··················\ ··················\ ··················\ ···················\ ················ 3 Installing the switch ··················\ ··················\ ··················\ ··················\ ··················\ ·································\ ··················\ ········· 4 Installing the switch in a 19-inch rack ··················\ ··················\ ··················\ ··················\ ··············· ··················\ ··················\ · 6 Mounting brackets ··················\ ··················\ ··················\ ··················\ ··················\ ··················\ ··················\ ···················\ ··· 7 Rack-mounting by using only front mounting brackets ··················\ ··················\ ··················\ ··················\ ··· ·············· 8 Rack-mounting by using front mounting brackets and a rack shelf ··················\ ··················\ ··················\ ············ 10 Rack-mounting by using front and rear mounting brackets ··················\ ··················\ ··················\ ················· ······· 10 Mounting the switch on a workbench ··················\ ··················\ ··················\ ··················\ ··················\ ··················\ ·············· 15 Grounding the switch ··················\ ··················\ ··················\ ··················\ ··················\ ················ ··················\ ··················\ ······ 15 Grounding the switch with a grounding strip ··················\ ··················\ ··················\ ··················\ ··················\ ··········· 15 Grounding the switch with a grounding conductor buried in the earth ground··················\ ··················\ ········· 17 Grounding the switch by using the AC power cord ··················\ ··················\ ··················\ ··················\ ··················\ 18 Installing/removing a power supply ··················\ ··················\ ··················\ ··················\ ··················\ ·· ··················\ ·············· 19 Installing a power supply ··················\ ··················\ ··················\ ··················\ ··················\ ··········· ··················\ ·············· 19 Removing a power supply ··················\ ··················\ ··················\ ··················\ ··················\ ··················\ ··················\ ······ 20 Connecting the power cord ··················\ ··················\ ··················\ ··················\ ··················\ ··········· ··················\ ··················\ · 21 Connecting the AC power cord ··················\ ··················\ ··················\ ··················\ ··················\ ··················\ ··············· 21 Connecting the PSR150-D to a –48 VDC power source ··················\ ··················\ ··················\ ··················\ ····· ····· 22 Connecting the switch to a +12 VDC output RPS ··················\ ··················\ ··················\ ··················\ ········· ············· 23 Connecting the switch to a –52 to –55 VDC output RPS ··················\ ··················\ ··················\ ··················\ ·· ········ 24 Installing/removing an interface card ··················\ ··················\ ··················\ ··················\ ················· ··················\ ·············· 24 Installing an interface card ··················\ ··················\ ··················\ ··················\ ··················\ ··················\ ··················\ ····· 25 Removing an interface card ··················\ ··················\ ··················\ ··················\ ··················\ ·········· ··················\ ··········· 26 Installing/removing a dedi cated CX4/SFP+ cable ··················\ ··················\ ··················\ ··················\ ········ ··········· 26 Verifying the in stallation ··················\ ··················\ ··················\ ··················\ ··················\ ·········· ··················\ ··················\ ········ 27 Accessing the switch for the first time ··················\ ··················\ ··················\ ··················\ ··············· ··················\ ·············· 28 Setting up the config uration environment ··················\ ··················\ ··················\ ··················\ ·············· ··················\ ············ 28 Connecting the console cable ··················\ ··················\ ··················\ ··················\ ··················\ ········ ··················\ ··················\ 28 Setting terminal parameters ··················\ ··················\ ··················\ ··················\ ··················\ ········· ··················\ ··················\ ··· 29 Powering on the switch ··················\ ··················\ ··················\ ··················\ ··················\ ·············· ··················\ ··················\ ····· 32 Changing the startup mode ··················\ ··················\ ··················\ ··················\ ··················\ ··················\ ··················\ ···· 35 Setting up an IRF fabric ··················\ ··················\ ··················\ ··················\ ··················\ ············ ··················\ ··················\ ··· 38 IRF fabric setup flowchart ··················\ ··················\ ··················\ ··················\ ··················\ ·········· ··················\ ··················\ ······ 38 Planning IRF fabric setup ··················\ ··················\ ··················\ ··················\ ··················\ ··········· ··················\ ··················\ ······ 39
iv Planning IRF fabric size and the installation site ··················\ ··················\ ··················\ ··················\ ··················\ ······ 39 Identifying the master switch and planning IRF member IDs ··················\ ··················\ ··················\ ··············· ······· 39 Planning IRF topology and connections ··················\ ··················\ ··················\ ··················\ ················· ··················\ ··· 40 Identifying physical IRF port s on the member switches ··················\ ··················\ ··················\ ··················\ · ············ 41 Planning the cabling scheme ··················\ ··················\ ··················\ ··················\ ··················\ ········· ··················\ ·········· 41 Configuring basic IRF settings ··················\ ··················\ ··················\ ··················\ ··················\ ······ ··················\ ··················\ ·· 42 Connecting the physical IRF ports ··················\ ··················\ ··················\ ··················\ ··················\ ··· ··················\ ················· 43 Accessing the IRF fabric to verify the configuration ··················\ ··················\ ··················\ ··················\ ·· ··················\ ······· 43 Maintenance and tr oubleshooting ··················\ ··················\ ··················\ ··················\ ··················\ ····· ··················\ ··········· 44 Password loss ··················\ ··················\ ··················\ ··················\ ··················\ ··················\ ····· ··················\ ··················\ ············ 44 Console login password loss ··················\ ··················\ ··················\ ··················\ ··················\ ········· ··················\ ·········· 44 Boot ROM passw ord loss ··················\ ··················\ ··················\ ··················\ ··················\ ·············· ··················\ ··········· 44 Power supply failure ··················\ ··················\ ··················\ ··················\ ··················\ ················ ··················\ ··················\ ········ 44 Fixed power supply failure ··················\ ··················\ ··················\ ··················\ ··················\ ·········· ··················\ ············· 44 Hot swappable power supply failure ··················\ ··················\ ··················\ ··················\ ··················\ ·· ··················\ ···· 46 Fan failure ··················\ ··················\ ··················\ ··················\ ··················\ ··················\ ······· ··················\ ··················\ ················ 46 Configuration terminal problems ··················\ ··················\ ··················\ ··················\ ··················\ ··················\ ··················\ ···· 46 Support and other resources ··················\ ··················\ ··················\ ··················\ ··················\ ········· ··················\ ················ 48 Contacting HP ··················\ ··················\ ··················\ ··················\ ··················\ ··················\ ····· ··················\ ··················\ ··········· 48 Subscription service ··················\ ··················\ ··················\ ··················\ ··················\ ················ ··················\ ··················\ 48 Related information ··················\ ··················\ ··················\ ··················\ ··················\ ················· ··················\ ··················\ ········· 48 Documents ··················\ ··················\ ··················\ ··················\ ··················\ ··················\ ········· ··················\ ··················\ ····· 48 Websites ··················\ ··················\ ··················\ ··················\ ··················\ ··················\ ·········· ··················\ ··················\ ······ 48 Conventions ··················\ ··················\ ··················\ ··················\ ··················\ ··················\ ······· ··················\ ··················\ ············· 49 Appendix A Technical specifications ··················\ ··················\ ··················\ ··················\ ··················\ · ··················\ ·········· 51 Physical specifications ··················\ ··················\ ··················\ ··················\ ··················\ ············· ··················\ ··················\ ········ 51 Chassis dimensions and weights ··················\ ··················\ ··················\ ··················\ ··················\ ······ ··················\ ······· 51 Ports and interfac e card slots ··················\ ··················\ ··················\ ··················\ ··················\ ······ ··················\ ············· 51 Chassis panel views ··················\ ··················\ ··················\ ··················\ ··················\ ··················\ ··················\ ···················\ ······ 52 A5500-24G EI (2 slots)/A5500-24G EI TAA (2 slots)/A5500-24G SI (2 slots) panel views ··················\ ··· 52 A5500-48G EI (2 slots)/A5500-48G EI TAA (2 sl ots)/A5500-48G SI (2 slots) panel views ··················\ ··· 53 A5500-24G-SFP EI (2 slots)/A5500-24G-S FP EI TAA (2 slots) panel views ··················\ ··················\ ·············· 54 A5500-24G-PoE+ EI (2 slots)/A5500-24G-PoE+ EI TAA (2 slots)/A5500-24G-PoE+ SI (2 slots) panel views ··················\ ··················\ ··················\ ··················\ ··················\ ··················\ ······· ··················\ ··················\ ····· 55 A5500-48G-PoE+ EI (2 slots)/A5500-48G-PoE+ EI TAA (2 slots)/A5500-48G-PoE+ SI (2 slots) panel views ··················\ ··················\ ··················\ ··················\ ··················\ ··················\ ······· ··················\ ··················\ ····· 56 Environmental specifications ··················\ ··················\ ··················\ ··················\ ··················\ ········ ··················\ ··················\ ··· 57 Power specifications ··················\ ··················\ ··················\ ··················\ ··················\ ················ ··················\ ··················\ ········ 57 Power input types ··················\ ··················\ ··················\ ··················\ ··················\ ··················\ · ··················\ ··················\ · 57 AC input voltage specifications ··················\ ··················\ ··················\ ··················\ ··················\ ····· ··················\ ·········· 57 RPS DC input voltage specificat ions and RPS compatibility ··················\ ··················\ ··················\ ··············· ········ 58 Power consumption specificatio ns for non-PoE switches ··················\ ··················\ ··················\ ··················\ · ·········· 58
v Power consumption specificat ions for PoE switches ··················\ ··················\ ··················\ ··················\ ····· ············· 58 Cooling system ··················\ ··················\ ··················\ ··················\ ··················\ ··················\ ···· ··················\ ··················\ ··········· 59 Appendix B FRUs and compatibility matrixes ··················\ ··················\ ··················\ ··················\ ············ ··················\ ···· 60 Hot swappable powe r supplies ··················\ ··················\ ··················\ ··················\ ··················\ ········ ··················\ ················ 60 Interface cards ··················\ ··················\ ··················\ ··················\ ··················\ ··················\ ··· ··················\ ··················\ ············· 61 SFP/SFP+/XFP transceiver modules and SFP+/CX4 cables ··················\ ··················\ ··················\ ··················\ ·· ··········· 61 GE SFP transceiver modules ··················\ ··················\ ··················\ ··················\ ··················\ ··················\ ··················\ ··· 62 FE SFP transceiver modules ··················\ ··················\ ··················\ ··················\ ··················\ ·········· ··················\ ············ 63 10-GE SFP+ transceiver modules ··················\ ··················\ ··················\ ··················\ ··················\ ··················\ ············· 63 SFP+ cables ··················\ ··················\ ··················\ ··················\ ··················\ ··················\ ··················\ ···················\ ··········· 64 10-GE XFP transceiver modules ··················\ ··················\ ··················\ ··················\ ··················\ ·························\ ········ 65 CX4 cables ··················\ ··················\ ··················\ ··················\ ··················\ ··················\ ··················\ ···················\ ············ 65 Appendix C Ports and LEDs ··················\ ··················\ ··················\ ··················\ ··················\ ··········· ··················\ ··············· 66 Ports ··················\ ··················\ ··················\ ··················\ ··················\ ··················\ ············· ··················\ ··················\ ··················\ ·· 66 Console port ··················\ ··················\ ··················\ ··················\ ··················\ ··················\ ······ ··················\ ··················\ ···· 66 10/100/1000Base-T Ethernet port ··················\ ··················\ ··················\ ··················\ ··················\ ····· ··················\ ··· 66 SFP port ··················\ ··················\ ··················\ ··················\ ··················\ ··················\ ·········· ··················\ ··················\ ········ 66 Combo interface ··················\ ··················\ ··················\ ··················\ ··················\ ··················\ ··················\ ···················\ ··· 67 LEDs ··················\ ··················\ ··················\ ··················\ ··················\ ··················\ ································\ ··················\ ··················\ · 68 System status LED ··················\ ··················\ ··················\ ··················\ ··················\ ··················\ · ··················\ ··················\ · 68 Power supply status LEDs ··················\ ··················\ ··················\ ··················\ ··················\ ············ ··················\ ·············· 69 RPS status LED ··················\ ··················\ ··················\ ··················\ ··················\ ··················\ ···· ··················\ ··················\ ···· 69 Port mode LED··················\ ··················\ ··················\ ··················\ ··················\ ··················\ ······ ··················\ ··················\ ·· 70 Seven-segment LED ··················\ ··················\ ··················\ ··················\ ··················\ ··················\ ··················\ ·················· 70 10/100/1000Base-T Ethernet port LED ··················\ ··················\ ··················\ ··················\ ··················\ ··················\ · 71 SFP port status LED ··················\ ··················\ ··················\ ··················\ ··················\ ················· ··················\ ··················\ · 72 Interface card status LED ··················\ ··················\ ··················\ ··················\ ··················\ ··················\ ··················\ ········· 73 Index ··················\ ··················\ ··················\ ··················\ ··················\ ··················\ ·······························\ ··················\ ·············· 74
1 Preparing for installation The HP A5500 EI & A5500 SI Switch Series includes the models in Table 1. Table 1 Models in the HP A5500 EI & A5500 SI Switch Series T ype Product code HP description Alias Non-PoE JD377A HP A5500-24G EI Switch with 2 Interface Slots A5500-24G EI (2 slots) JG250A HP A5500-24G EI TAA Switch with 2 Interface Slots A5500-24G EI TAA(2 slots) JD375A HP A5500-48G EI Switch with 2 Interface Slots A5500-48G EI (2 slots) JG251A HP A5500-48G EI TAA Switch with 2 Interface Slots A5500-48G EI TAA (2 slots) JD374A HP A5500-24G-SFP EI Switch with 2 Interface Slots A5500-24G-SFP EI (2 slots) JG249A HP A5500-24G-SFP EI TAA Switch with 2 Interface Slots A5500-24G-SFP EI TAA (2 slots) JD369A HP A5500-24G SI Switch with 2 Interface Slots A5500-24G SI (2 slots) JD370A HP A5500-48G SI Switch with 2 Interface Slots A5500-48G SI (2 slots) PoE JG241A HP A5500-24G-PoE+ EI Switch with 2 Interface Slots A5500-24G-PoE+ EI (2 slots) JG252A HP A5500-24G-PoE+ EI TAA Switch with 2 Interface Slots A5500-24G-PoE+ EI TAA (2 slots) JG240A HP A5500-48G-PoE+ EI Switch with 2 Interface Slots A5500-48G-PoE+ EI (2 slots) JG253A HP A5500-48G-PoE+ EI TAA Switch with 2 Interface Slots A5500-48G-PoE+ EI TAA (2 slots) JG238A HP A5500-24G-PoE+ SI Switch with 2 Interface Slots A5500-24G-PoE+ SI (2 slots) JG239A HP A5500-48G-PoE+ SI Switch with 2 Interface Slots A5500-48G-PoE+ SI (2 slots)
2 Safety recommendations WARNING! Before installation and operation, read all of the safety instructions i\ n the Compliance and Safety Gui de supplied with your device. This section provides general recommendations. For more information, see the Compliance and Safety Guide . • Turn off all power and remove all power cables before opening the chassis. • Unplug all power and external cabl es before moving the chassis. • Locate the emergency power-off switch before in stallation and shut off power immediately if necessary. • Always wear an ESD-preventive wris t strap when installing the device. • Do not stare into the open optical interface. Th e high-power density light can burn the retina. • Use a good grounding system to protect your ro uter against lightning shocks, interference, and ESD. This is essential to the operating reliability of your switch. • Make sure that the resistance between the chassis and the ground is less than 1 ohm. Installation site requirements The following tables provide info rmation about temperature and humidity, cleanness, and air quality requirements. To ensure normal operation of the router, make sure that the room temperature meets the requirements described in Table 2. Table 2 Temperature r equirements Tem perature Range Operating temperature Long term: 0°C to 45°C (32°F to 113°F) Short term: –10°C to +55°C (14°F to 131°F) (no more than 96 hours of continuous operation in less than 15 days in one year) Storage temperature –40°C to +70°C (–40°F to +158°F) CAUTION: If condensation appears on the router when you move it to a high-temperature environment, dry the router before powering it on to avoid short circuits.
3 Maintain appropriate humidity in your equipment room, as described in Table 3. Table 3 Humidity requ irements Humidit y Range Operating humidity (noncondensing) 5% to 95% Storage humidity (noncondensing) 5% to 95% Lasting high relative humidity tends to cause p oor insulation, increased electricity consumption, mechanical property change of materials, and corrosion of metal parts. Lasting low relative humidity is likely to result in loose screws due to washer contract ion, and even ESD, which causes the circuits to fail. Table 4 Dust concentration limit in the equipment room Ph ysical active substance Concentration limit (particles/m3) Dust particle ≤3 x 104 (No visible dust on desk over three days) Note: Dust particle diameter ≥ 5 μm Table 5 Limits on harmful gases in the equipment room Gas Ma x concentration (mg/m3) SO2 0.2 H2S 0.06 NH3 0.05 Cl2 0.01 Rack-mounting requirements Before rack-mounting a switch, make sure the rack meets the following requirements: • HP recommends that the switch is mounted in an op en rack. If you mount a switch in a closed rack, make sure there is a good heat dissipation system. • The rack is steady enough to support the switch and accessories. • The switch fits the rack size. Leave some space be side the left and right panels of the switch for chassis heat dissipation. Installation tools • Flathead screwdriver • Phillips screwdriver • Needle-nose pliers • Wire-stripping pliers • Diagonal pliers • ESD-preventive wrist strap • Blow dryer All these installation tools are user supplied.
4 Installing the switch CAUTION: Keep the tamper-proof seal on a mounting screw on the chassis cover intact, and if you want to open the chassis, contact HP for permission. Otherwise, HP will not be liable for any consequence caused thereby.
5 Figure 1 Hardware installation flow No Start Install the switch to a 19-in rack or workbench Ground the switch Install hot swappable power supplies? Yes Install hot swappable power supplies Connect the power cords Verify the installation Power on the switch Operating properly?Power off the switch Troubleshoot the switch Install interface cards? Yes YesNo No Install interface cards Operating properly? Yes No Troubleshoot the switch End Install transceiver modules, connectors, and cables