Have a look at the manual Honeywell thermostat ST9100S 1 Day Service Time Switch User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 178 Honeywell manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
11 OPer ATING YOU r ST9100S Overriding the Operation Without Changing the Programme In AUTO and ONCe operating modes, the OVerr ID e button switches the system ON or OFF without altering the programme. When the indicator lamp is ON, pressing the OVerr ID e button switches the system OFF until the next programmed ON time. When the indicator lamp is OFF, pressing the OVerr ID e button switches the system ON until the next programmed OFF time. The LoT™ Display will provide you with information about the override. The e xtra Hour Function The eXT r A HOU r button allows you to switch the system ON for up to 3 extra hours without altering the programme. Pressing the button once will give one extra hour. The LoT™ Display will display the message ‘+ 1 HOUR’, to confirm the button has been pressed. When the green INDICATOr LA m P is OFF, pressing the eXT r A HOU r button switches the system ON for just one hour. When the green INDICATOr LA m P is ON, pressing the eXT r A HOU r button extends the programmed ON period by one hour. Further presses of the eXT r A HOU r button will increase the extra hour period by one hour for each button press, up to a maximum of 3 hours. The LoT™ Display will continue to provide information on the extra hour status. To cancel the extra hours, just keep pressing the eXT r A HOU r button until the ‘CANCELLED’ message appears on the LoT™ Display.
12 FINe TUNING YOU r ST9100S Changing from Am /P m Time Display to the 2 Hour Clock Your ST9100S can operate on the 12 hour AM/PM or 24 hour clock formats. To change the format, ensure the slider is in the rUN position then press and hold the and buttons together for about 2 seconds. Ignore the ‘NOT VALID’ message that will appear briefly. All the displayed times will be automatically changed to the new format. Repeating this procedure will change the clock display back to the original format. Changing the Installer Parameters The ST9100S has a special Installer Mode where some features can be adjusted to suit your lifestyle or preferences – these are called Installer Parameters, and are listed in the table below, along with a description of the options that are possible. INSTALL er PAr A me T erParameter NumberDefault ValueOptionsDescription 24hr or am/pm clock display.11212, 2412 = am/pm display,24 = 24hr display Configure backlight operation.220, 1, 20 = off, 1 = on if button pressed,2 = on continuously Enable/disable auto time change.310, 10 = disabled, 1 = enabled Number of ON/OFFs per day.522, 32 = 2 on/offs per day,3 = 3 on/offs per day Select default time programme.6AA, b, CA = standard, b = at home,C = economy Reset all parameters810, 10 = do not reset1 = default parameters
1 FIN e TUNING YOU r ST9100S To e nter Installer m ode: a. Ensure the slider is in the rUN position, then press and hold and buttons together for 8 seconds. Ignore the ‘NOT VALID’ message that is displayed for a few seconds. The message ‘SET UP MENU’ will show briefly, followed by ‘SET INSTALLER OK ?’ b. Press the button to take you into the Installer Mode Parameter Menu. c. Parameter 1 is now available to change. This is to allow you to change the clock format from 12 hour AM/PM to 24 hour. At every step, the LoT™ Display will inform you what the parameter means and what option you have selected. The parameter number is shown on the display separated by a colon from the parameter value. d. You can change the parameter value by pressing the or buttons. At this point the description in the LoT™ Display will change and the parameter value will flash. If you press the value will stop flashing and be saved for use. e. Press to move to the next parameter available for editing. f. Keep pressing to step around the list of parameters, and use or buttons to change the parameter value. g. Any parameter changes that have been confirmed with the button will be saved and used. To e xit Installer m ode: h. You can exit Installer Mode at any time by moving the slider to the next position and then back again to rUN. Note: Installer Mode will exit automatically after 10 minutes if the slider is not moved.
1 FAQ AND T r OUBL e SHOOTING How do I set the time only, if the ST9100S clock is not correct? Your ST9100S contains a very accurate digital clock that is factory pre-set. Should you ever need to change the time, just follow this procedure: a. Move the slider to the DAY/TI me position. b. Keep pressing the green button until the message ‘SET THE TIME’ is displayed. To change the time, press the or buttons until the correct time is shown. The message ‘IS TIME OK?’ will be displayed. Press the green button to confirm the time is correct. If you have made a change, the message ‘TIME SAVED’ will show, followed quickly by ‘DATE + TIME COMPLETE’. c. Move the slider to the rUN position, to complete changing the time. What do I do when the clocks go back in October and forward in m arch? Your ST9100S is factory-set to adjust the clock automatically at the correct dates, so you should never need to adjust the clock forward or backwards yourself. It is possible to disable this particular feature, as described in the section ‘Changing the Installer Parameters’ (page 12). You may also check the section ‘Configuration & Service Data’ (page 18) to see how your Installer has configured your product. What should I do if I get ‘lost’ while programming the ST9100S? The LoT™ Display on ST9100S will provide you with help and tips to work through the programming. Should you ever get ‘lost’, the simplest thing to do is to move the slider to the rUN position, and then move it back to the appropriate programming position where you got lost. At this point just follow the instructions again. What happens if there is a power failure? In the event of a mains power failure, the ST9100S display will go blank, the indicator lamp will go out, and the control output will switch off. The real time will be constantly maintained by means of the built-in battery backup, ready to power back up as if nothing had happened when the mains power is restored. In addition, all programmes and settings are stored in a special memory (called NV memory) which requires no power to maintain information, and so will be retained indefinitely. Should the correct time and date ever be lost, for whatever reason, the message ‘SET DATE + TIME’ will be displayed whilst the slider is in the rUN position. In this case, simply follow the procedure described under ‘Step 1: Setting the Date & Time’ (page 4). It should not be necessary to make any changes to your programmes.
1 Troubleshooting Guide This is a quick guide to help you diagnose and cope with possible problems with ST9100S. For further assistance, please contact your Installer. FAQ AND T r OUBL e SHOOTING SymptomPossible Causeremedy ST9100S has a blank LCD displayNo power to the heating systemCheck that there is power to the heating system Fault in ST9100SCall Installer ST9100S indicates that the system is ON, but radiators are cold and/or taps are running with cold water. Temperature controls are switched off or set too low Check that the temperature controls in the system are set to appropriate levels Boiler or other system controls have malfunctioned Call Installer ST9100S shows the message: ‘INTERNAL FAULT’ Fault in ST9100SCall Installer Every few seconds, the ST9100S screen shows the message: ST9100S is counting down the number of days until your next boiler service is due. Arrange a boiler service before the counter reaches zero. After servicing your boiler, the Service Engineer / Installer will reset the ST9100S to remind you when the next boiler service is due. Each service is normally a maximum of 1 year apart. Although the heating is still operating, the ST9100S screen keeps flashing the message: Your boiler service is OV er DU e.Arrange an immediate boiler service. After servicing your boiler, the Service Engineer / Installer will reset the ST9100S to remind you when the next boiler service is due. Each service is normally a maximum of 1 year apart. The ST9100S screen shows the message:Your boiler service is OVer DU e and the boiler has been automatically switched off to ensure your safety. Arrange an immediate boiler service. If set to do so, it may be possible to obtain limited use of the boiler by pressing any eXT r A HOU r button. Each button press will allow operation of the boiler for 1 hour at a time, and the screen will display the message “On 1h”. After servicing your boiler, the Service Engineer / Installer will reset the ST9100S to remind you when the next boiler service is due. Each service is normally a maximum of 1 year apart.
16 BOILer S er VIC e rem IND er By Law, your gas boiler should be inspected once a year to ensure it is operating safely. Your ST9100S Programmer has a range of features designed to help make sure this service is carried out at the correct time. These features will be programmed by your Installer, maintenance Engineer, or Landlord. • If it has been set to do so, ST9100S will display a message on the screen to remind you that a boiler service is due. • If the service is overdue, the Programmer may switch off the heating system, to ensure your safety. If this happens you must arrange an immediate service visit. Contact details should be listed on page 19 of this guide, in the section Boiler & System Service Log. • A contact telephone number may also have been programmed into the ST9100S. If so, a message will appear on the LoT™ Display indicating the number you should call. Countdown to Service Your ST9100S can indicate a countdown for the number of days until your service is due. This message will appear on the screen every few seconds, to give you an opportunity to schedule a service visit. When Service is Due When your boiler service is OVer DU e the words “Ser VIC e DU e ” will continue to flash on your screen, and you should arrange an immediate service visit.
17 Shut-down If your ST9100S shows the words “Ser VIC e DUe ” and “OFF” then your boiler service is OVer DU e and the boiler has been automatically switched off to ensure your safety – you should arrange an immediate service visit. If set to do so, it may be possible to obtain limited use of the boiler by pressing the eXT r A HOU r button. Each button press will allow operation of the boiler for 1 hour at a time, and the screen will display the message “On 1h” as shown. However, you should still arrange an immediate service visit, as this will allow you to comply with the law and ensure your gas boiler is operating safely. BOILer S er VIC e rem IND er
150022737-003 A CONFIGU r ATION & S er VIC e DATA Configurable FeaturesOptionsInstaller Configured (tick appropriate box) 24hr or am/pm clock displayam/pm display 24hr display Display backlight operationOff On if button pressed On continuously Automatic time changeEnabled Disabled Number of ON/OFFs per day2 on/offs per day 3 on/offs per day Default programmeA = standard b = at home C = economy Configuration Data (to be completed by Installer) The table below is for the Installer to complete to indicate how your ST9100S has been configured.