    Have a look at the manual Honeywell Sundial RF Pack 3 Wireless Enabled Programmer and Thermostats User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 178 Honeywell manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							31
    SymptomPossible CauseRemedy
    ST9420C shows the 
    message ‘NO SIGNAL’ and 
    a flashing radiator symbol 
    DT92E shows a flashing RF 
    symbol 
    Your DT92E 
    batteries are 
    running low on 
    power. Change the DT92E batteries 
    (see page 21 for how to do this).
    RF communication 
    path between 
    ST9420C and 
    DT92E is blocked, 
    possibly by a metal 
    object. Check direct path between both 
    products and re-position any 
    objects that may be blocking 
    the signal.
    Relocate the DT92E, if possible.
    ST9420C shows the 
    message ‘NO SIGNAL’ and 
    a flashing tap symbol 
    .
    CS92A communications 
    failure indication (Press 
    CS92A button and red light 
    comes on. Note – light 
    will switch off after approx 
    1 minute to save battery 
    power). Your CS92A 
    batteries are 
    running low on 
    power.
    Change the CS92A batteries. 
    This is located next to your hot 
    water storage tank (see page 
    25 for description of how to 
    change the batteries).
    RF communication 
    path between 
    ST9420C and 
    CS92A is blocked, 
    possibly by a metal 
    object. Check direct path between both 
    products and re-position any 
    objects that may be blocking 
    the signal.
    ST9420C shows the message 
    ‘NO SIGNAL’ and a flashing 
    flame symbol 
    Red light on BDR91T (if 
    installed) is lit continuously. RF communication 
    path between 
    ST9420C and 
    BDR91T is blocked, 
    possibly by a metal 
    objectCheck direct path between both 
    products and re-position any 
    objects that may be blocking 
    the signal
    ST9420C shows the 
    message ‘SENSOR FAULT’ 
    and a flashing radiator 
    symbol 
    DT92E display shows ‘’ and a flashing spanner 
    symbol   Fault with DT92E
    Call Installer
    FAQ  AND TROUBLESHOOTING 
    						
    							32
    FAQ  AND TROUBLESHOOTING
    SymptomPossible CauseRemedy
    ST9420C shows the 
    message ‘SENSOR FAULT’ 
    and a flashing tap symbol 
    CS92A sensor error 
    indication (Press CS92A 
    button and red light blinks 
    0.5s on, 0.5s off. Note – light 
    will switch off after approx 
    1 minute to save battery 
    power). CS92A sensor 
    cable may be 
    disconnected from 
    the wiring terminals.
    Re-connect the sensor wired to 
    the CS92A terminals.
    Fault with CS92A Call Installer 
    						
    							33 
    						
    							3450047645-008 A
    CONFIGURATION & SERVICE DATA
    Configuration Data (to be completed by Installer)
    The tables below are for the Installer to complete to indicate how your ST9420C and 
    DT92E have been configured.
    Application
    Insert application number as per Installation wiring diagrams:
    Configurable FeaturesOptionsFactory 
    settingInstaller configured 
    (tick box or note value)
    ST9420C Configuration - standard
    24hr or am/pm clock 
    display. am/pm display
    24hr display
    Display backlight operation. Off
    on if button pressed
    on continuously
    Automatic time change.disabled,
    enabled
    1-day or 5/2-day or 7-day 
    operation.1-day operation
    5/2-day operation
    7-day operation
    Number of ON/OFFs per 
    day.2 on/offs per day,
    3 on/offs per day
    Default time programme.
    A = standardb = at home
    C = economy
    Hot water set temperature From 40 to 85°C60°C
    Optimum start no optimum start
    delayed start
    optimum start on
    Optimum start limit 1 hour
    2 hours
    3 hours
    Optimum stop disabled
    enabled
    Frost protection temperature From 5 to 16°C5°C
    Minimum ON/OFF time 1, 2, 3, 4, 5 minutes1 minute
    Cycle rate 3, 6, 9, 12 cycles 
    per hour6 cycles
    Proportional band width From 1.5 to 3.0°C1.5°C
    Failsafe mode (loss of RF 
    communications) off
    on 20% 
    						
    All Honeywell manuals Comments (0)