Haier Hrf 369aa Service Manual
Here you can view all the pages of manual Haier Hrf 369aa Service Manual. The Haier manuals for Fridge freezer are available online for free. You can easily download all the documents as PDF.
Page 12
1 Program Diagram Start T>Ts Read T Stop Read T T>Ts Ts+Td>t>Ts Ts+Td+2t>T>Ts+Td+t Ts+Td+2t>T>Ts+Td+t Ts+Td+mt>T>Ts+Td+(m-1)t N=Nmax Ts+Td>t>Ts Ts+Td+t>T>Ts+Td N=Nmax Y Y N Stop N>N2 N>N3 N=N1 N=Nmax-1 N>N4 N=N2 N=N3 N>Nmax-1 T ---- Factual Temperature Ts ----- Enactment Temperature Td----- No~Off Extent t ------ Temperature Increment N----- Compressor Rotate Speed N1< N2< N3< ……..< Nmax Program Diagram
Page 13
2 Maintenance Service and Trouble Shooting 1 No cooling Maintenance Service and Trouble Shooting Block by ice or dirty things,change filter and change refrigerant again.YES If compressor can run naturally and temperature raising of condenser is very low YESNO No cooling If compressor can run after it stop to run five minutes and give power.NO !When charging refrigerant,we must notice to make...
Page 14
3 2 The compressor doesn’t stop 1 The thermostatwas set at the coldest position. 2 The ambient temperature is very high or the refrigerator is near by heat resource. 3 The door was opened too many times or there are more fresh food inside. Check and repair the main control panelNOIscooling capacity insufficient. YES YESNO Comprossor doesnt stop Does the refrigerator refrgerate?NO Adjust and instruct consumer how to use.NOCheck and repair according to the section of Cooling capacity is...
Page 15
4 3 Cooling capacity is insufficient YESRepair Does the refrigerant leak siowly?.NO Is the ambient temperature low than 16℃YES Adjust and instruct consumer how to use. Check the therostat is correct?Cooling capacity is insufficient Maintenance Service and Trouble Shooting
Page 16
5 4 The compressor doesn’t work Check the therostat is correct?Check the power source and power cord? Does the control panel has 220V power output?Check and repair the control panel. Does the compressor has 220V power output? Check and repair compressor and accessory.YESYESNO Check all cords and power cords. Is the ambient temperature low than 16℃ Does the refrigerated room lamp illuminate when the door is opened? The compressor doesnt work.YESNO YESYESNO RepairAdjust and...
Page 17
6 5 Normal Phenomena—Not Troubles for Refrigerators In a domestic refrigerator, there is not only a complicated electric control system, but also a refrigerating system that is difficult to discern whether it is in a good working condition. Both the systems are related and affect each other. If a certain part of a refrigerator works abnormally .Its refrigerating efficiency will decrease ,operation properties will become unstable ,or even it cannot be used normally for those serious cases....
Page 18
7 6 Common Troubles in Refrigerators and Their Remedies Causes for troubles occurring in refrigerators are closely related to the quality of components and workmanship in assembling by manufacturers as whether refrigerators are properly used and maintained .The parameters generally used to express the working conditions of a refrigerator include the temperature inside the refrigerator ,operation rate ,electric power consumption ,noise level ,and other functional indexes .If any one of these...
Page 19
8 Hums from a fully enclosed aggregate unit is the sound caused by overload indicating that the motor cannot be started normally ,meanwhile ,a clattering sound can be heard from inside the start relay ,which is produced because the start contacts cannot be released normally .A whistling sound is caused by the high pressure gas flowing out of the crack of the pressure tube inside the compressor ,and clucks are the sound of striking after the suspended spring inside the compressor has broken ....
Page 20
9 ambient temperature ,this means that most meshes of its screen has been clogged ,resulting in an obstructed flowing of refrigerant ,thus causing a drop in temperature due to throttling . d) Feel the temperature of exhaust gas from the refrigerating system .the exhaust gas should be very hot and this is the normal working state .For those refrigerator with enclosed type of compressor refrigerating system, no frost or dew drop will from on the gas suction tube ,otherwise ,there is something wrong...