Home > Comdial > Communications System > Comdial DIGITECH Digital Telephone System Instructions Manual

Comdial DIGITECH Digital Telephone System Instructions Manual

Here you can view all the pages of manual Comdial DIGITECH Digital Telephone System Instructions Manual. The Comdial manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 141

Press ITCM t # 7 4 6 +k for base level.I
:EATURE DESCRIPTION
&count Codes: Account codes are usec
) identify calls by category, or by any
Ither desired grouping, so that costing by
lat category or grouping can be
worded. An account code can be a
minimum of three numbers and a
maximum of eight numbers.
r
12
1
iNTRY CODE AND PROMPTING DISPLAY
. Dial 75.“SMDA PROGRAMMING
‘. Dial 05 to configure account codes.
“SETACCT. CODE ”
a. Dial account oode number (000 - 999).
b. Dial 
# plus next account number.
c....

Page 142

Press ITCM +k # 7 4 6 ‘Ik for base level.IFEATURE DESCRIPTION
Account Codes: 
(continued)
Account Code Dlsplay: As a feature for
users of LCD speakerphones, 
a remindel
message can be programmed to appear
on the station display to prompt the user
to enter an account code during 
incomiry
and/or outgoing calls. The message
display time is programmable.
ENTRY CODE AND PROMPTING DISPLAYREFERENCE RECORD
6. Dial 09 to program the account code maximum
length.
“MAXACCT. CODE X”
- Dial 3 - 6 for number of digits...

Page 143

rPress ITCM % # 7 4 6 +# for base level.I
f:
L
‘EATURE DESCRIPTION
itatlon Message Detall Accounting
SMDA) Prlntout: Call 
cost reports,
broduced by the system for printing, are
lenerated automatically whenever the
system detects that the records storage
krea is ninety-five percent full. Program
he system to automatically generate
hese reports for printing at a certain time
!ach day if desired.
Statlon Message Detall Reportlng
:SMDR) Prlntout: Program the system
‘or the SMDR to provide continuous
xtntout...

Page 144

ATTENDANT CONFIGURATION
Mark the desired selections in the charts to record programming needs.
Dial the feature code and then dial the selection code or press the programming button to program the selection.
fOTE: A current program setting is indicated by a lighted LED next to fhe programming button for that selection.When a foggle (on/off) action
is provided by a single button, the lighted LED indicates when the feature is active.
:EATlJRE DESCRIPTION
3ase Level: The first step in any
rrogramming...

Page 145

IPress ITCM +k #I 7 4 6 % for base level.I
‘EATURE DESCRIPTION
iystem Speed Dial - continuedENTRY CODE AND PROMPTING DISPLAY- Dial 91 - 94 for line group l-4.
“LINE GROUP 1”
- Press R’CM button for intercom line.“INTERCOM 
”
5. Dial number for storage (32 digits max).
“XXXXX.. . ”
- If required, press HOLD button to store a pause.
- If required, press TAP button to store a hookflasl
6. Press TRANSKONF button to save the number.
7. Repeat steps 2-6 for all speed dial numbers.
-OR-
Press % for...

Page 146

SYSTEM SPEED DIAL RECORD 

Page 147

.cd
Press ITCM % # 7 4 6 f for base level.I
FEATURE DESCRIPTION
Nlght Transfer 
(of ringing): The
attendant can place the system into the
night transfer (of ringing) mode of
operation. While in this mode, special
line/station ringing assignments are
enabled.
NOTE: See night transfer of tinging on
page 4-37 for line/station
ringing assignments
MUSIC on Hold: Music is provided to
outside lines that are placed on hold if
an external music source is connected
to the system. Music on hold can be
disabled by...

Page 148

rtire% ITCM t # 7 4 6 t for base level.
IFEATURE DESCRIPTION
Statlon Names: Stations can be
assigned individual names or category
names that will be displayed by an LCD
speakerphone when it is called by the
station. Typical names could be TEC
SER, MKT 
1, J Smith.Statlon Message Detall 
Accounting
(SMDA) Printout: The attendant can
command the system to print several
different types of SMDA reports and to
delete all stored SMDA records.
NOTE: The departmental call
distribution report 
ref/ecfs...

Page 149

IMl66-083System Programming j
SECTION 3
VIDEO DISPLAY TERMINAL PROGRAMMING
INTRODUCTION
The class of service can be programmed from a video
display terminal (VDT) instead of from the
programming station. The VDT that is used must be a
serial-data, 
W-232 type, asynchronous device. A
keyboard send/receive (KSR) hard-copy printer can be
used instead of a VDT if preferred.
A personal computer (PC) can be employed if it will
run a communications software program which allows
it to emulate a data terminal...

Page 150

System ProgrammingIMI 66-083
PROCEDURE
1.
2.
3.
4.
5.
Determine the system programming parameters,
and record them for future reference.
Turn on the AC power to the system and the VDT.
Press the RETURN (ENTER) key. The system
enters an approximate 20 second timeout cycle.
Step 4 must be performed within this timeout period
or the programming sequence will be aborted.
Type the password: I 
% 7 4 6 t, and press
RETURN (ENTER). The VDT will display the main
programming menu. The system enters an
approximate...
Start reading Comdial DIGITECH Digital Telephone System Instructions Manual

Related Manuals for Comdial DIGITECH Digital Telephone System Instructions Manual

All Comdial manuals