Anaheim Stepper MLP0864101 Addendum User Manual
Have a look at the manual Anaheim Stepper MLP0864101 Addendum User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 523 Anaheim manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
March 2006 Addendum - MLP08641-01 Addendum - MLP08641-01Addendum - MLP08641-01 Addendum - MLP08641-01 Addendum - MLP08641-01 #L010219 This version of the MLP08641 has an additional opto-isoltaed output for notifying the user of a fault condition. The output is on a 4 pin mini-fit jr. style connector and has two 24 inch leads for it. The wire colors for the output are as follows: Red/White - This is the collector of the optically isolated fault output. When a fault occurs, this output will conduct current into the emitter. Black/White - This is the emitter of the optically isolated fault output. Warning: There is no current limiting resistor or components in the fault out circuit so care care must be taken to not pass more than 20Ma of current through this transistor. Absolute Maximum Ratings for Fault Out Output VCE: 35VDC VEC: 0.5VDC IC: 20mA RED/WHITE BLACK/WHITE