    Have a look at the manual Anaheim Stepper MLP070815 vs 80VDC Driver Comparison User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 523 Anaheim manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							L010136 - MLP07081 vs 80 VDC Driver Comparison.doc910 E. Orangefair Lane
    Anaheim, CA 92801
    Tel (714) 992-6990
    Fax (714) 992-0471
    http://www.anaheimautomation.com
    MLP07081 vs 80 VDC Driver Comparison
    The chart shows that the MLP07081, which has a 160 VDC bus, generates more than 50 percent more torque and more than
    50 percent more power at speeds greater than 10 RPS.  The MLP07081 can also accelerate the motor faster due to its higher
    bus voltage enabling the driver to quickly obtain the necessary current in the motor winding causing the rotor to move into
    the correct position faster during the rapid acceleration.MLP07081 vs 80 VDC Driver using 34R314
    0 100 200
    300 400 500
    600
    700
    800
    900 1000 1100
    1200
    05101520253035404550
    SPEED (RPS)TORQUE (oz-in)0 50
    100
    150 200 250
    300
    350
    400
    450 500 550
    600POWER (Watts)MLP07081 Torque80 VDC Driver TorqueMLP07081 Power80 VDC Driver Power 
    						