Home > Anaheim > Stepper > Anaheim Stepper 23MD Series Product Release

Anaheim Stepper 23MD Series Product Release

    Download as PDF Print this page Share this page

    Have a look at the manual Anaheim Stepper 23MD Series Product Release online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 523 Anaheim manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							April 2003 #L010131
    910 East Orangefair Lane, Anaheim, CA 92801
    e-mail: [email protected](714) 992-6990  fax: (714) 992-0471
    website: www.anaheimautomation.com
    ANAHEIM AUTOMATION
    23MD Series Motor / Driver CombinationPRODUCT RELEASE
    • Step Motor / Microstep Driver Combination
     Eliminates Motor Wires
     Encoder Options Available
     Microstep Divisors of 8, 4, 2, or Full Step
     Compact Package
     12-24V Power Requirement
     TTL Logic or 24V Level Inputs Available
     Ideal for Precise Positioning
     0.225
    o Resolution at Eighth Step
     Efficient and Durable
     Long Life Expectancy
    The 23MD Series is a compact construction that implements a microstepping
    driver and a step motor in one streamline package. With the two parts combined into
    one casing, the need to include motor wires has been eliminated. The high-torque step motor can generate up to
    230 oz-in of torque. The microstepping driver will operate off 12VDC minimum to 24VDC maximum with a maxi-
    mum power intake of 40W. The inputs are capable of running from either open collector or TTL level logic outputs,
    or sourcing 24VDC outputs from PLCs. The microstepping driver features resolutions from 200 - 1600 steps/
    revolution, providing smooth rotary operation. The 23MD series comes in either a single-shaft version or a double-
    shaft version with optional encoder and motor stack lengths of 1/2, 1, 2, or 3 allowing for varying amounts of start-
    up torque and inertia. The 23MD series features include built in over temperature and short circuit shut down,
    automatic 70% reduction in current after clock pulses stop being received, and status LED’s to indicate power on
    (green LED) and clocks being received (yellow LED).       
    						