    							PneuCal IV
    The 2500T offers
    simplistic set-up to
    make your job
    easier.
    The Altek Pneu-Cal IV is a highly accurate, digital calibrator for pneumatic
    field instrumentation, including valve actuators, P/I transmitters, controllers,
    gauges, switches and recorders. It is especially suitable for checking 3 to 
    15 PSI systems. Its dual precision regulators enable output of set and variable
    pressures to control devices, while the switching manifold allows fast selection
    among the pressure ports. The unit simultaneously displays pressure and mA,
    and has a built-in loop power supply. Accuracy is ± 0.035% of full scale for
    all ranges.
    Each Unit Includes: Built - In Switch Testing, AC Adapter/Charger, Test Leads, 
    Hard Shell Carrying Case, Instructions.
    664 PNEUMATIC CALIBRATOR SPECIFICATIONS
    Features:
    nHigh Accuracy Ð 0.035% FS
    n1-51 mA Inputs
    nSwitch Test Inputs
    n100 PSID Internal Sensor
    nBuilt-In 24 VDC Loop Power
    nTemperature Compensated
    From -10û to 50ûC 
    (13û to 122ûF)
    nSelectable Engineering Units
    nLightweight Ð Just 12 Pounds
    nDual Digital Display Ð 
    PSI and mA
    Unless otherwise indicated, all specifications are referred to an ambient temperature of 
    23ûC ±1ûC (72ûF ±2ûF).
    Pressure Ranges/Resolution: -5.00 to 100.00 PSI, -34.47 to 680.00 kPa
    Pressure Accuracy: ±0.035% FS PSI (over -10 to +50ûC range)
    Pressure Engineering Units: PSI; Pa; kPa; MPa; BAR; mBAR; atm; kgf/cm
    2; mm Hg; 
    in Hg @ 0ûC and 15ûC, in H
    2O: 4ûC,15ûC, 20ûC, 23ûC; mm 
    H20 @ 4ûC and 23ûC; cm H2O @ 4ûC and 23ûC
    Electrical Engineering Units: mA; % of 4-20 mA; % of 10-50 mA
    Electrical Input Connections: Double insulated, full-size banana jacks
    mA Input Range: 1-51 mA
    mA Resolution: 0.001mA
    mA Accuracy: ±0.01% FS
    Temperature Effect: 0.005%/ûC (mA Input only)
    Loop Power: 24 VDC, ±20%, 25 mA max. (When loop power is enabled, 
    the discharge rate on the batteries exceeds the charging 
    capacity of the 16 VDC adapter.)
    Switch Test: Dry contacts only. (Display will freeze when switch test inputs 
    change state. Press RESET key to resume normal operation.)
    Operating Temperature: -10ûC to 50ûC (13ûF to 122ûF)
    Storage Temperature: -30ûC to 85ûC (-22ûF to 185ûF)
    Zero Adjustment: Via front panel push-button (pressure only)
    Display: 2-line,16 character alpha-numeric display
    Power: Internal Ni-Cd batteries or 16 VDC adapter. (To charge battery 
    the unit has to be powered off.)
    Battery Life (typical): 23 hrs. (1 hr. with 24 VDC transmitter power at 20 mA)
    Dimensions (h x w x d): 6x13.5x12   
    PHONE: 1-800-322-5835 ¥ FAX: 716-349-3510E-MAIL: [email protected] ¥ WEB: www.altekcalibrators.com 
    						