INSTRUCTIONS FOR CONTINUED AIRWORTHINESS - 206EC-270M-1 Revision H Page 5 The low pressure (suction) line from the compressor is attached to the evaporator lines, and causes the refrigerant to be pulled out of the receiver-drier and through the expansion valves. The expansion valves serve as a controlled spray orifice, to spray the correct amount of refrigerant into the evaporator. This regulation of refrigerant allows the liquid to absorb the heat from the cabin air, and transform it to a...
Page 12
INSTRUCTIONS FOR CONTINUED AIRWORTHINESS - 206EC-270M-1 Revision H Page 6 15. Refrigeration Cycle Schematic (PLEASE NOTE: This illustration is provided as a reference only and may not match actual installation) Figure 1: Refrigeration Cycle Illustration High pressure liquid Low pressure vapor Low pressure liquid High pressure vapor Compressor Condenser Evaporator Receiver Drier Bottle Bypass Valve Expansion Valves Evaporator
Page 13
INSTRUCTIONS FOR CONTINUED AIRWORTHINESS - 206EC-270M-1 Revision H Page 7 CHAPTER 2 AIRWORTHINESS LIMITATION SECTION The Airworthiness Limitations section is FAA approved and specifies maintenance required under paragraph 43.16 and 91.403 of the Federal Aviation Regulations unless an alternate program has been FAA approved. 1. Airworthiness Limitations No airworthiness limitations associated with this design change
Page 14
INSTRUCTIONS FOR CONTINUED AIRWORTHINESS - 206EC-270M-1 Revision H Page 8 CHAPTER 3 INSPECTIONS 1. INSPECTION REQUIREMENTS: Periodic Inspections (Hours Are Aircraft time) Item Annual Every 200 hours of operation Special inspection instructions. Fwd Evaporator Blower X Check for operation throughout entire speed range of blower operation. Aft Evaporator Blower X Check for operation throughout entire range of speed for blower operation. Condenser blower motor...
Page 15
INSTRUCTIONS FOR CONTINUED AIRWORTHINESS - 206EC-270M-1 Revision H Page 9 2. INSPECTION PROCEDURES. NOTE Refer to “Chapter 4 Location and Access” to locate all components for inspection. A. Inspection of the FWD and AFT evaporator blower motors CAUTION Fans are designed to operate with the resistance of the entire ducting system. Operation of the evaporator fans with any part of the distribution system removed may cause permanent damage to the fan motor. WARNING Fans may take up...
Page 16
INSTRUCTIONS FOR CONTINUED AIRWORTHINESS - 206EC-270M-1 Revision H Page 10 c. Connect 28V ground power to the aircraft and place the A/C mode switch in the “A/C” position and verify that: 1. Condenser scoop opens. 2. Condenser fan is activated and operating. This fan should pull air into the aircraft through the open scoop and exit at the screen below the condenser. 3. Compressor clutch is engaged. Verify compressor clutch engagement by visually observing the clutch plate clamp to the...
Page 17
INSTRUCTIONS FOR CONTINUED AIRWORTHINESS - 206EC-270M-1 Revision H Page 11 Figure 2: Belt Tension Inspection D. Inspection of air conditioner placards and markings. a. Check all air conditioner placards and markings for security and legibility. E. Inspection of air conditioner compressor assembly NOTE: The air conditioning system must be serviced with refrigerant to perform this inspection. a. Connect 28V ground power to the aircraft and place the A/C mode switch in the “A/C”...
Page 18
INSTRUCTIONS FOR CONTINUED AIRWORTHINESS - 206EC-270M-1 Revision H Page 12 H. Inspection of Compressor Drive system a. Cut the safety wire on the belt tensioning link assembly jam nuts and adjust the tensioning link assembly to loosen the compressor drive belt. b. Check S-3520 drive pulley for play relative to the tail rotor drive shaft, both in the direction of rotation as well as for lateral movement relative to the shaft, and inspect area around the base of the drive ring at the shaft for...
Page 19
INSTRUCTIONS FOR CONTINUED AIRWORTHINESS - 206EC-270M-1 Revision H Page 13 CHAPTER 4 LOCATION AND ACCESS 1. LOCATION OF AIR CONDITIONER FEATURES Nomenclature Description of Location Air Conditioner Control Panel The air conditioner control panel is located in the existing overhead circuit breaker panel between the pilots and co-pilots seats. Forward (Flight Deck) Evaporators The forward evaporator(s) are mounted to the center pedestal below the instrument panel in the chin...
Page 20
INSTRUCTIONS FOR CONTINUED AIRWORTHINESS - 206EC-270M-1 Revision H Page 14 Figure 3: Layout of Air Conditioning Single Fwd Evaporator Electrical Instl Aft Evaporator Instl Condenser Instl Fwd Evaporator Instl Air Distribution System Compressor Instl Condenser Instl Air Outlets