    Have a look at the manual Air Vent Inc. Continuous Soffit Vent Installation Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 38 Air Vent Inc. manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							Application procedures and conditions are beyond the control of the manufacturer
    and/or seller of Continuous Soffit Vent and for this reason neither manufacturer nor
    seller can be responsible for the failure of the product when not used according to
    instructions and specifications.
    Form 14014-8/03 © 2003 Air Vent, Inc.
    3000 West Commerce, Dallas, TX 75212
    309-692-6969  FAX: 1-800-635-7006
    www.airvent.com
    CONTINUOUS SOFFIT VENT INSTALLATION INSTRUCTIONS 
    Model SV201 & SV351
    Requires two cuts in soffit for installation. Correct
    location is as close as practicable to facia. For new
    construction or for installation on existing structures.
    MODEL SV202 & SV352
    Installs next to the facia with only one cut in the soffit
    required for installation. Vertical flange fits against rafter
    ends (facia goes over flange), assuring that the vent will
    be positioned correctly along outer edge of the soffit.
    For new construction only Ð or remodeling involving
    replacement of facia.
    Continuous Soffit Vent always installs correctly, since arrangement of louvers is same from either
    side. Intake airflow from each side meets above vent to create gentle turbulence assisting fallout
    of snow and rain before it is carried to insulation.
    Net Free
    Area Per Units/
    Part Model Length Lin. Ft. Ctn. Material Color
    84300 SV201 MF 8« 9 sq. in. 50 .014ý alum. mill finish
    84302 SV201 WH 8« 9 sq. in. 50 .014ý alum. white
    84304 SV201 BR 8« 9 sq. in. 50 .014ý alum. brown
    84306 SV202 MF 8« 9 sq. in. 50 .014ý alum. mill finish
    84307 SV202 WH 8« 9 sq. in. 50 .014ý alum. white
    84308 SV202 BR 8« 9 sq. in. 50 .014ý alum. brown
    90320 SV351 WH 8« 9 sq. in. 50 vinyl white
    90325 SV351 BR 8« 9 sq. in. 50 vinyl brown
    90254 SV352 WH 8« 9 sq. in. 50 vinyl white
    SPECIFICATIONS 
    						
    							CONTINUOUS SOFFIT VENT 
    INSTALLATION INSTRUCTIONS 
    Continuous Soffit Vent can be combined with all types of
    high ventilators for a balanced ventilation system. It installs
    in the soffit as close as practical to the facia and offers
    these advantages:
    ¥  Continuous Soffit Vent provides a continuous vent 
    opening for uniform distribution of intake air across the 
    underside of the roof sheathing.
    ¥  Continuous Soffit Vent keeps infiltrating snow and 
    rain away from ceiling insulation with a special louver 
    pattern. Intake air from half of the louvers is directed 
    toward the flow of air from the other half, creating a 
    gentle turbulence that permits snow and rain to fall out 
    of the air stream onto the vent or adjacent soffit, rather
    than being carried to the insulation. 1/8ý louver 
    openings prevent entrance of flies, bees, wasps and 
    other insects Ð yet are large enough to avoid being 
    clogged by dust and dirt.
    ¥  Continuous Soffit Vent installs easily on almost all 
    types of construction.MODEL SV202 & SV352
    3/4ý
    3/8ý
    3/8ý2ý
    3/8ý
    3/8ý
    3/8ý2ý
    Model SV201 & SV351
    The most effective airflowthrough the attic space is provided by
    low intake venting located along the soffit, combined with high
    venting for exhaust. Research and experience have shown that
    ridge vents are the ideal high venting, providing a uniform flow of
    air along the underside of the roof sheathing and along the entire
    ridge to help prevent summertime heat buildup and wintertime
    moisture condensation. However, regardless of the type of high
    vents used, a continuous soffit vent along the outer edge of the
    eave provides proper air intake. 
    						