    							WIRING DIAGRAM:
    Aiphone Communication Systems
    1700 130th Ave. N.E.
    Bellevue, WA  98005
    (425) 455-0510
    FAX (425) 455-0071
    MKW-DK/A Instr.
    0812JD
    Toll Free Technical Support:
    1-800-692-0200
    E-mail [email protected]
    +
    -
    Power 
    Supply
    1A1
    1A2
    L
    L
    +
    -
    Aiphone Monitor
    Motion Detector*
    WhiteYellow
    MKW-DK/AMust be installed within 2 of door station.
    Installation Guidelines:
    1. The motion detector must provide a normally open momentary contact
    . A Photoelectric beam, pressure 
    pad, or remote call button can also be used to activate the video door station.
    2. MKW-DK/A must be installed within 2 feet of video door station. The unit is not weather resistant, so it should    
    be installed in a protected enclosure, preferably in the box behind the video door station.
    3. The MKW-DK/A can be used to connect a motion detector to all JA, JF, and KC Series video door stations.
    Contact Aiphone for information on getting remote activation on other video units.
    4. The above diagram is representative of the installation of the MKW-DK/A to an Aiphone video system. 
    Terminal designations on the monitor/adaptor will vary slightly depending on the system being installed. 
    Note:
    For complete system installation, please refer to the instruction manuals included with the video system. 
    Door Strike
    PT-1210N
    (AC Transformer)
    Remote Activation Interface Adaptor for Video Door Stations
    The MKW-DK/A Adaptor allows any standard motion detector or activation device with a normally open 
    contactto be interfaced with the JA, JF, or KC Series video door station. When the activation device is 
    tripped, the camera will turn on, and a chime will be heard at the inside monitor station(s), indicating that 
    there is some activity near the door station location.  
    - INSTRUCTIONS -
    A1
    A2
    Video Door 
    Station
    * Use any activation device that provides a        
    normally openmomentary dry closure.Motion DetectorRemote Mushroom push button PIR detectorPressure Pad
    MKW-DK/A Dimensions (HxWxD):