    							Door StrikePT-1210N
    (AC Transformer)
    A1
    A2
    WIRING DIAGRAM:
    Aiphone Communication Systems
    1700 130th Ave. N.E.
    Bellevue, WA  98005
    (425) 455-0510
    FAX (425) 455-0071
    KB-DAR-M Instr.
    0703bkjs
    Toll Free Technical Support:
    1-800-692-0200
    E-mail [email protected]
    Motion Detector*
    White
    Installation Guidelines:
    1. The motion detector must provide a normally open momentary contact
    .A Photelectric beam, pressure
    pad, or remote call button can also be used to activate the video door station.  
    2. The KB-DAR-M works with the KB system only. Standard KB-DARs can be used in the same system if they
    are not interfaced with a remote activation device.    
    Note:
    Only information concerning the use of the KB-DAR-M is shown here. 
    For complete system installation, please refer to the instruction manuals included with the video system. 
    KB-DAR Modified for Motion Detector Interface 
    The KB-DAR-M allows any standard motion detector or activation device with a normally open contactto 
    be interfaced with the KB-3MRD Video System. When the motion detector is tripped, the camera will turn 
    on and a chime will be heard at the inside monitor station(s), indicating that there is some activity near 
    the door station location.  
    - INSTRUCTIONS -
    KB-DAR-M
    White
    A1
    A2
    KB-DAR
    +
    -
    PS-2420UL
    1A1
    1A2
    2A1
    2A2
    B1
    B2
    +
    -
    KB-3MRD
    Yel
    Org
    1A1
    1A2
    +
    -
    KB-3HRD
    * Or any signaling  
    device that provides a   
    normally open
    momentary dry closure. 
    Aiphone 871802 wire
    Aiphone 871802 wire
    871802 Motion Detectors with N/O Contacts:
    Detection Systems DS720I
    Pulnix 6612
    Intellisense 8140S
    Ademco 1998PI
    Sentrol AP750  
    						