Home > Aiphone > Telephone > Aiphone C123LW Instructions User Manual

Aiphone C123LW Instructions User Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Aiphone C123LW Instructions User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 161 Aiphone manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							Component
    Module*- INSTRUCTIONS -C-123LW
    DUAL MASTER CHIME-COM SYSTEM
    Set contains: 1 C-D Door Station, 2 C-ML/A Masters & 1 DAK-2S KitAiphone Communication Systems
    1700 130th Ave. N.E.
    Bellevue, WA  98005
    (425) 455-0510
    FAX (425) 455-0071C-123LW
    092898bkjd OPERATION NOTES:
    1.  Only one master can be used at a time.
    2.  If both masters are activated, a feedback will be heard through the system when either TALK button is pressed.
    3.  If feedback occurs, wait approximately 15 seconds, or until the master turns off automatically. At that time,
         communication can continue normally.
    INSTALLATION GUIDELINES:
    1.  Use 2 conductor wire from the door station to the first master, then to the second master.
    2.  Install the units at the desired locations.
    3.  Separate SKK-620 power supplies, or four C batteries are required for each master station.
    4.  DO NOT install both a power supply and batteries at any one master.
    5.  Install the bare wire leg of the component module directly onto the 1 terminal of the C-ML/As.
    6.  Attach the wire coming form the 1 terminal of the C-D to the colored wire end of the component modules at both
         masters. (The component modules will easily fit within the space available.)
    7.  Connect the E terminals between the door station and master stations.
    8.  If door release is included, use a separate 2-conductor wire from the L terminals of the masters through an AC
         transformer and to the door strike.
    9.  The EL-9S is designed for a standard wood framed door, and for light and medium usage. If a different type of door is
         used, install a strike appropriate for the door.
    10. The door release button on the master station is a Normally Open contact closure.C-D1
    E+
    - SKK-6201
    E
    +
    -
    L
    L C-ML/AComponent
    Module*+
    - SKK-6201
    E
    +
    -
    L
    L C-ML/ADoorMaster #1
    Master #2EL-9SPT-1210N
    (AC Transformer)Please read and understand all
    instructions before installation.IMPORTANT!!!
    Each master REQUIRES an SKK-620 power supply (or batteries).
    TOLL FREE TECHNICAL SUPPORT:
    (800) 692-0200
    TOLL FREE FAX LINE:
    (800) 832-3765
    TECHNICAL SUPPORT E-MAIL:
    [email protected] * Install bare wire
      end to 1 terminal
      (DAK-2S contains two
      component modules, one
      for each master station.) 
    						