    							AX MASTER OPTIONS VIA THE 6 PIN CONNECTOR
    Brown V+ To Coax Core
    Red V- To Coax Braid
    Orange
    Yellow
    Green
    Blue
    +
    -
    PS-2420UL
    RY-ES
    White
    Blue
    Red
    Black
    APPLICATION DIAGRAM
    To Bell 
    & Power
    Orange
    Orange
    1010JD-AX 6-pin options
    AX-8M/AX-8MV
    Standard 9 
    Monitor
    5 Max
    Normally Open 
    Dry Input1. Connect Brown (V+) and Red (V-) to coax input of standard 
    monitor.  Maximum wire run is 5.  Output is 1Vp-p 75ohm.
    2. Connect Orange and Yellow wires to an IER-2 for chime 
    extension or to the White and Blue wires of the RY-ES for 
    external device signaling.
    3. Connect the Green and Blue wires to any normally open dry 
    contact device.  To be used in place of the talk button on 
    master.  Contact device should be no more than 50 from the 
    master. 
    						